4.3. PDEX COUNTER
The PDEX electronic counter is the historical predecessor of the PDEX5 counter. It is set very similarly to
the PDEX5 counter, see chapter 4.1, with the same remote controllers PDERT‐5S (service) and PDERT‐5O
(manager). Using the controllers, it is possible to perform:
read non‐resettable electronic quantity totalizers of all delivery hoses
read and reset daily electronic quantity and financial totalizers of all hoses
setting of unit prices of products (in manual operation)
reading and setting of operating parameters of the dispenser
The operator and manager mode of the PDEX counter is almost identical to the same mode of the PDEX5
counter. The only difference is in the numbers of the individual parameters. Below tables describe the
lists of operator and manager parameters of the PDEX counter. The last column in the table indicates the
corresponding parameter of the PDEX5 counter, see chapter 4.1.
Table 29 ‐ List of PDEX counter operator access mode parameters and differences from PDEX5
Parameter Meaning
01
Non‐resettable quantity totalizers
02
Daily quantity totalizers
03
Product unit prices (in manual mode)
04
Current time and date
05
Program version and CRC (check sums)
06
Error message code history
07
Fuelling history
Table 30 ‐ List of PDEX counter manager access mode parameters and differences from PDEX5
Parameter Meaning
01
Non‐resettable quantity totalizers
02
Daily quantity totalizers
03
Product unit prices (in manual mode)
04
Current time and date
05
Program version and CRC (check sums)
06
Error message code history
07
Fuelling history
08
Manager mode access password
09
Maintenance history
10
‐ not used ‐
11
‐ not used ‐
12
Dispenser control mode
13
Error message code statistics
14
Current product temperature
15
Daily totalizers reset
16
Working check number
17
Display intensity control
18
Display text messages
19
Display segment error
TATSUNO EUROPE a.s., www.tatsuno‐europe.com
Corresponding PDEX5 parameter / Differences
P00
P01, P02
P03
P04 / backup time = max 5 days
P05
P20 / 10 records for filling point A and B
P25, P26 / 10 records for filling point A and B
Corresponding PDEX5 parameter / Differences
P00
P01, P02
P03
P04 / backup time = max 5 days
P05
P20 / 10 records for filling point A and B
P25, P26 / 10 records for filling point A and B
P08
P29 / 10 records without time/date stamp
‐
‐
P12/it is not possible to disable the transition from
automatic to manual
P21, P22/ common statistics for filling points A and B
P14 / + temperature near the processor
P15
‐
‐
‐
‐