No.
Item code
P-7
37
Proportional band (PID group 7)
I-7
38
Integral time (PID group 7)
d-7
39
Derivative time (PID group 7)
rE-7
40
Manual reset (PID group 7)
oL-7
41
Manipulated variable lower limit (Output limiter group 7)
oH-7
42
Manipulated variable upper limit (Output limiter group 7)
P-8
43
Proportional band (PID group 8)
I-8
44
Integral time (PID group 8)
d-8
45
Derivative time (PID group 8)
rE-8
46
Manual reset (PID group 8)
oL-8
47
Manipulated variable lower limit (Output limiter group 8)
oH-8
48
Manipulated variable upper limit (Output limiter group 8)
P-9
49
Proportional band (PID group 9)
I-9
50
Integral time (PID group 9)
d-9
51
Derivative time (PID group 9)
52
rE-9
Manual reset (PID group 9)
oL-9
53
Manipulated variable lower limit (Output limiter group 9)
54
oH-9
Manipulated variable upper limit (Output limiter group 9)
P-A1
55
Proportional band (PID group A1) 100.0
I-A1
56
Integral time (PID group A1)
d-A1
57
Derivative time (PID group A1)
rE-A1
58
Manual reset (PID group A1)
CP-A1
59
Switching point (PID group A1) 1000 SPU
tP-A1
60
Tuning point (PID group A1)
P-A2
61
Proportional band (PID group A2) 100.0
I-A2
62
Integral time (PID group A2)
d-A2
63
Derivative time (PID group A2)
rE-A2
64
Manual reset (PID group A2)
CP-A2
65
Switching point (PID group A2) 2000 SPU
tP-A2
66
Tuning point (PID group A2)
P-A3
67
Proportional band (PID group A3) 100.0
I-A3
68
Integral time (PID group A3)
d-A3
69
Derivative time (PID group A3)
rE-A3
70
Manual reset (PID group A3)
CP-A3
71
Switching point (PID group A3) 3000 SPU
tP-A3
72
Tuning point (PID group A3)
Item
Factory default
settings
100.0
0
0
50.0
0.0
100.0
100.0
0
0
50.0
0.0
100.0
100.0
0
0
50.0
0.0
100.0
0
0
50.0
500 SPU
0
0
50.0
1500 SPU
0
0
50.0
2500 SPU
DCP551 Parameter Work Sheet
User
Settings and descriptions
-
settings
0.0 to 1000.0%
(0.0: On-off control)
0 to 3600sec
(0: no integral operation)
0 to 1200sec
(0: no derivative operation)
0.0 to 100.0%
–5.0 to manipulated variable upper limit %
Manipulated variable lower limit to +105.0%
0.0 to 1000.0%
(0.0: On-off control)
0 to 3600sec
(0: no integral operation)
0 to 1200sec
(0: no derivative operation)
0.0 to 100.0%
–5.0 to manipulated variable upper limit %
Manipulated variable lower limit to +105.0%
0.0 to 1000.0%
(0.0: On-off control)
0 to 3600sec
(0: no integral operation)
0 to 1200sec
(0: no derivative operation)
0.0 to 100.0%
–5.0 to manipulated variable upper limit %
Manipulated variable lower limit to +105.0%
0.0 to 1000.0%
(0.0: On-off control)
0 to 3600sec
(0: no integral operation)
0 to 1200sec
(0: no derivative operation)
0.0 to 100.0%
–19999 to +20000 SPU
–19999 to +20000 SPU
0.0 to 1000.0%
(0.0: On-off control)
0 to 3600sec
(0: no integral operation)
0 to 1200sec
(0: no derivative operation)
0.0 to 100.0%
–19999 to +20000 SPU
–19999 to +20000 SPU
0.0 to 1000.0%
(0.0: On-off control)
0 to 3600sec
(0: no integral operation)
0 to 1200sec
(0: no derivative operation)
0.0 to 100.0%
–19999 to +20000 SPU
–19999 to +20000 SPU
9