C-5.2 Load Limiter; C-5.2.1 Description Of The Controls; C-5.2.2 Operation - Terex Genie GTH-4013 Operator's Manual

Hide thumbs Also See for Genie GTH-4013:
Table of Contents

Advertisement

C-5.2
LOAD LIMITER
On the front top strut of the cab, there is limiter 34
which warns the operator of the variation of stability of
the machine and blocks any manoeuvre before the
same reaches a critical condition.

C-5.2.1 Description of the controls

1 Calibration selection button
2 Display
3 Stability indicator with LED-bar
4 Green light – power OK
5 Yellow light – calibration mode
6 Calibration confirmation button
7 Not used
8 Red light – outrigger position
9 Buzzer ON/OFF pushbutton
10 Red light –overload pre-alarm / alarm
The digit on display 2 shows the selected attachment.
The user can choose among:
0: Generic
1: Platform

C-5.2.2 Operation

When power is turned on, light 4 comes on. The display
2 remains off and the monitoring system runs a self-
test before displaying the digit corresponding to the
used attachment on display 2. At this time, the system
is activated.
During operation, the led-bar 3 lights up gradually
depending on the variation of stability.
Green LED's: during normal operation when the
percentage of overturning moment is
between 0 and 89, these LED's are ON.
The machine is stable.
Yellow LED's: they light up when the machine tends
to overturn and the percentage of
overturning moment with respect to the
threshold value is between 90 and 100.
The system enters the pre-alarm mode,
light 10 flashes and the buzzer sounds
with an intermittent sound.
Handler with telescopic boom GTH-4013
OPERATING INSTRUCTIONS
4
Red LED's:
Example of use of the overload warning system
C-32
Page
Document 57.0007.0200 - 01/2006
1
2
3
5
6
7
risk of overturning: the percentage of
overturning moment is above 100 with
respect to the threshold value.
The machine enters the alarm mode:
light 10 is lit, the buzzer sounds
continuously and any dangerous
manoeuvre is blocked. The operator can
only retract the load within safety limits.
Boom extension
without outriggers
Overload warning
system in alarm
Boom retraction
Alarm ceases
Lowering of the outriggers
or reduction of the load to
be handled
10
9
8

Advertisement