C-5.2.2 Alarm Codes And Resetting - Terex Genie GTH-4013 Operator's Manual

Hide thumbs Also See for Genie GTH-4013:
Table of Contents

Advertisement

DANGER
Before using the machine, make sure that the first
green LED of the overload warning system is ON.
The overload warning system must not be used to
check the load going to be lifted: it has only been
designed to signal possible unbalances of the
machine along its motion axis.
Such unbalances may also be caused by an abrupt
operation of the levers during the load handling. If,
during work, several indicators light up, operate the
levers more smoothly.
Handler with telescopic boom GTH-4013
OPERATING INSTRUCTIONS
The limiter has diagnostic facilities to aid in the
identification of failures of the transducers, breakages
of the cables or defects of the electronic system.
When a failure is signalled, the limiter enters the safety
mode blocking any dangerous manoeuvres. Lights 5,
8 and 10 start flashing, the buzzer start sounding and
an error message is shown on the display.
The meaning of the error messages is shown in Section
E "Faults and Troubleshooting".
C-33
Page
Document 57.0007.0200 - 01/2006
C-5.2.3 Alarm codes and resetting
5
10
8

Advertisement

Table of Contents
loading

Table of Contents