PROBLEM
IMPORTANT
In case of faults not listed in this chapter, address to the GENIE Technical Assistance, your nearest
authorised workshop or dealer.
Handler with telescopic boom GTH-4013
FAULTS AND TROUBLESHOOTING
CAUSES
4 Block relay error during operation
5-6-7-8 Block relay error when power
is turned on
9 CELL 1 and CELL 2 reading
incongruence. The values read from
the two cells are different.
A Data error in RAM
B Outrigger incongruence
C Error in A.D.C. reading check
E-5
Page
Document 57.0007.0200 - 01/2006
SOLUTIONS
• Check the efficiency of relay and
wiring
• Stop and restart the machine and
check the outputs. If the error
message is still shown, address to
the GENIE service centre to replace
the DLE unit.
• Check the efficiency of relay and
wiring
• Stop and restart the machine and
run a new test. If the error message
is still shown, address to the GENIE
service centre to replace the DLE
unit.
• Check that the cells are intact and
fixed correctly. If the error message
is still shown, address to the GENIE
service centre to replace the load
cell or re-calibrate the machine.
• Stop and restart the machine. If the
error message is still shown,
address to the GENIE service
centre.
• An input is not read. Check the
wiring, the power cord and the
connector of the DLE unit. If the
error message is still shown,
address to the GENIE service
centre.
• Stop and restart the machine. If the
error message is still shown,
address to the GENIE service
centre.