PROBLEM
CHECKING THE MICRO-SWITCHES
WHEN THE DLE IS IN ALARM, THE
BOOM IN/OUT MOVEMENTS, THE
OUTRIGGER UP-MOVEMENT AND
THE MACHINE SWAY FUNCTION
REMAIN ACTIVATED
CHECKING THE MICRO-SWITCHES
WITH THE BOOM RAISED 2
METRES ABOVE THE GROUND THE
OUTRIGGER UP-MOVEMENT AND
THE MACHINE SWAY FUNCTION
REMAIN ACTIVATED
THE DLE LOAD LIMITING SYSTEM
IS IN ALARM
ERROR MESSAGES OF THE DLE
LOAD LIMITING SYSTEM SHOWN
ON THE DISPLAY
Handler with telescopic boom GTH-4013
FAULTS AND TROUBLESHOOTING
CAUSES
• Check that the connectors are
correctly plugged in the actuator
• Check that the connectors are
correctly plugged in the actuator
• Fuse blown (F25 - 10 A)
• System failure
1 E2PROM error
2 The value read from CELL 1 is higher
than max permissible
3 The value read from CELL 2 is higher
than max permissible
E-4
Page
Document 57.0007.0200 - 01/2006
SOLUTIONS
• If the connectors are plugged in
correctly, contact the GENIE
Technical Assistance
• If the connectors are plugged in
correctly, contact the GENIE
Technical Assistance
• Check and replace fuse, if
necessary
• Stop and restart the machine to
RESET the system. If the error
message is still shown, address to
the GENIE service centre to re-
calibrate the machine.
• Check the wiring between control
panel and load cell
• Check that the load cell is fixed
correctly
• Check the connecting cable or the
connectors is/are not shorted
• If the error message is still shown,
address to the GENIE service centre
and let the load cell be checked.
• Check the wiring between control
panel and load cell
• Check that the load cell is fixed
correctly
• Check the connecting cable or the
connectors is/are not shorted
• If the error message is still shown,
address to the GENIE service centre
and let the load cell be checked.