D-5.2.3 Fuel; D-5.2.4 Grease; D-5.2.5 Engine Coolant - Terex Genie GTH-4013 Operator's Manual

Hide thumbs Also See for Genie GTH-4013:
Table of Contents

Advertisement

D-5.2.3 Fuel

Refuel through cap A. Use only Diesel fuel with less
than 0.5% sulphur content, according to the
specifications of the diesel engine operation handbook.
ATTENTION
In cold climates (temperature under -20
"Arctic" type Diesel fuel, or oil-diesel fuel, or oil-
diesel fuel mixtures. The composition of the latter
can vary in relation to the ambient temperature up
to max. 80% oil.

D-5.2.4 Grease

For the machine greasing, use:
• Lithium-based
Vanguard LIKO
grease, type EP2
• Graphitized AGIP
grease, type GR NG 3
• INTERFLON FIN
GREASE LS 2
ATTENTION
Avoid mixing greases of different type or features
and do not use greases of lower quality.
Handler with telescopic boom GTH-4013
MAINTENANCE
°
C) use only
When greasing by pump
When greasing by brush
For the telescopic boom
sliding blocks
Document 57.0007.0200 - 01/2006

D-5.2.5 Engine coolant

It is advisable to use an antifreeze mixture (50% water-
50% antifreeze). At the delivery, the machine is refilled
with:
TEREX PRO COOL by VALVOLINE
The use of this product guarantees protection to the
circuit for 3 years or 7000 hours without having to add
any dry coolant additive.
Protection against boiling / freezing
Product
%
33
40
50
70
ATTENTION
Use an antifreeze mixture in the proportions
recommended by the manufacturer in relation to
the ambient temperature of the jobsite.
D-32
Page
TEREX PRO COOL
Freezing
point
-17 °C
-24 °C
-36 °C
-67 °C
Boiling
point
123 °C
126 °C
128 °C
135 °C

Advertisement

Table of Contents
loading

Table of Contents