■ B-2.3
WORKING CLOTHES
During work, but especially when maintaining or
repairing the machine, operators must wear suitable
protective clothing:
Overalls or any other comfortable garments.
Operators should not wear clothes with large
sleeves or objects that can get stuck in moving
parts of the machine.
Protective helmet.
Protective gloves.
Working shoes.
IMPORTANT
Use only type-approved working clothing in good
condition.
■ B-2.4
PERSONAL PROTECTIVE EQUIPMENT
Under special working conditions, the following
personal protective equipment should be used:
Breathing set (or dust mask).
Ear-protectors or equivalent equipment.
Goggles or facial masks.
IMPORTANT
Use only type-approved protective equipment in
good condition.
Handler with telescopic boom GTH-4013

SAFETY PRECAUTIONS

■ B-3.1
Always take into account the features of the job site
where you are going to work:
The machine is not electrically insulated and does
not provide protection from contact with or
proximity to electrical power lines.
Always keep at a minimum safe distance from the
telescopic boom and the lifted load. Electrical
hazards!
Do not at any time use the machine during a storm.
B-4
Page
Document 57.0007.0200 - 01/2006
B-3 SAFETY PRECAUTIONS

HAZARDS ON THE JOBSITE

Always examine the working area and compare it
with the machine dimensions in the different
configurations.
DANGER
DANGER
DEATH OR INJURY CAN RESULT FROM
CONTACTING ELECTRIC POWER LINES.
ALWAYS CONTACT THE ELECTRIC POWER LINES
OWNER. THE ELECTRIC POWER SHALL BE
DISCONNECTED OR THE POWER LINES MOVED
OR INSULATED BEFORE MACHINE OPERATIONS
BEGIN
POWER LINE VOLTAGE REQUIRED CLEARANCE
0 to
50 to
200 to
350 to
500 to
750 to
Keep away from the machine in case of contact
with energized power lines. Personnel on the
ground must never touch or operate the machine
until energized power lines are shut off.
DANGER
50 kV
10 ft
3.00 m
200 kV
15 ft
4.60 m
350 kV
20 ft
6.10 m
500 kV
25 ft
7.62 m
750 kV
35 ft
10.67 m
1000 kV
45 ft
13.72 m