11 TROUBLESHOOTING
Error
Error
code
detail
The proximity sog has been turned OFF
1092
1
before it reached to the cramp speed in
the proximity dog type OPR.
The OPR direction and push direction
1094
1
are opposite in the stopper type OPR.
"Torque limit (
1095
1
b13)" has not been turned ON at
stopper type OPR.
"AL96" has occuured in the servo
amplifier, and the OP setting has been
1096
1
failed.
Even after 1000[ms] passed at OPR
stop, in-position was not achieved.
Even after 1800[ms] passed at OPR
1097
1
stop, in-position was not achieved.
When the dog cradle type, proximity
dog type or limit switch combined type
OPR is used, the movement amount
1098
1
moved to detect the proximity dog
signal or zero point exceeded the value
set in "
Pr.62
When the scale origin signal direction
type OPR, or dog cradle type, proximity
dog type and limit switch combined type
using the incremental linear scale is
1100
2
used, "Need to pass motor Z phase
after the power supply is switched on" is
not set in "
Pr.397
4".
The setting value of software stroke
1
limit exceeded the setting range at OPR
start.
1101
The setting value of software stroke
2
limit exceeded the setting range at first
PLC READY ON.
The backup data for current value
restoration is wrong.
The OPR has not been executed after
1
setting the absolute position system.
1201
The servo parameter "
direction selection" was changed.
The backup data for current value
2
restoration cannot be saved normally.
Oparation errors (1000 to 1899) (Continued)
Error
At proximity dog OFF
At stopper type OPR
Servo status 1:
Md.40
start
At OPR stop
At OPR stop
(Before setting of the
distance to Z phase)
When the movement
amount of oppsite
direction against of
OPR direction passed
the "OP search limit".
OP search limit".
At OPR start
Function selection C-
At OPR start
At first PLC READY ON
At PLC READY ON
Rotation
Pr.314
At OPR completion
Operation status at
Error check
error occurrence
The sudden stop/OPR
is not completed.
The stopper type OPR
is not completed.
The OPR is not
completed.
Sudden stop
The OPR does not
start.
The OPR does not
start.
(The OPR request
turns ON.)
The OPR request
turns ON.
(The current value
does not restored.)
The current value
does not restored.
The OPR is not
completed.
11 - 8
MELSEC-Q
Remedy
Lengthen the proximity dog. Or,
adjust the OPR speed to stop on
the proximity dog.
Set the OPR direction to be the
same as the push direction.
Execute push, and after turning
the torque limit on, start OPR.
Adjust the servo amplifier so that it
stabilizes quickly at OPR stop.
(1) Reduce the OPR speed and
creep speed.
(2) Lengthen the OPR time
constant.
(3) Broaden the in-position range.
(1) Confirm the input status of
proximity dog signal, etc.
(2) Confirm the setting value of OP
serch limit.
Set "Need to pass motor Z phase
after the power supply is switched
on" in "
Function selection
Pr.397
C-4".
Set the value of software stroke
limit within the range.
(Refer to Section 10.4.2.)
Execute the OPR.
Replace the QH74MH.