5 SPECIFICATIONS AND FUNCTIONS
5.1.3 Output signals (PLC CPU
Device No.
Y0
PLC READY
Y1
All axis servo ON
Y2
Forced stop input
Y10
Axis 1
Y11
Axis 2
Y12
Axis 3
Y13
Axis 4
Y14
Axis 5
Y15
Axis 6
Y16
Axis 7
Y17
Axis 8
Positioning
start
Y18
Axis 9
Y19
Axis 10
Y1A
Axis 11
Y1B
Axis 12
Y1C
Axis 13
Y1D
Axis 14
Y1E
Axis 15
Y1F
Axis 16

QD74MH)

Signal name
ON : PLC READY
ON
OFF : PLC READY
OFF
ON : Servo ON
OFF : Servo OFF
ON : Requested
OFF : Not requested
ON : Requested
OFF : Not requested
(a) This signal notifies the QD74MH that the PLC CPU is normal.
• It is turned ON/OFF with the sequence program.
(b) This signal turns OFF at the change of the basic parameters or OPR
parameters.
(c) The following processes are executed at the PLC READY signal ON.
• The setting range check of the basic parameters, OPR parameters and
system parameters.
• Unit READY signal [X0] ON
(d) The following processes are executed at the PLC READY signal from ON
to OFF.
• Unit READY signal [X0] OFF
• Sudden stop of operating axis.
• The servo ON/OFF is executed for all servo amplifiers connected to the
QD74MH.
([READY ON, Servo ON] / [READY OFF, Servo OFF])
• The forced stop is requested from the PLC CPU to the QD74MH.
• Positioning, OPR and new current change is started.
• The positioning start signal becomes valid at the leading edge, and the
operation is started.