10 FUNCTION DETAILS
Select "1: Valid (Used absolute position detection system" in
detection system" of servo parameter to use as the absolute position system.
Be sure to install a battery for retaining the location of the OPR in the servo amplifier.
POINT
When the servo parameter "
from "1: Valid (Used absolute position detection system" to "0: Invalid (Used in
incremental system)", the established machinery position before change becomes
invalid. Execute again the OPR to used as the absolute position system.
Absolute position detection system" is changed
Pr.303
10 - 41
MELSEC-Q
Absolute position
Pr.303