Parameter
Seam Parameter
Stitch length
Needle thread tension
Sewing foot pressure
Differentiation
Type of differentiation
Seam segment length
or
Number of stitches in segment
Max. Speed
It is possible to reduce the maximum
sewing speed at this point. The
maximum sewing speed can be set in
the software at the Technician level.
Operating Instructions 878-M PREMIUM - 06.0 - 11/2021
6.7.7
Setting the
There are various options for setting the parameters in the seg-
ment. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
parameters
Segment
Settings
Value range
0.1 to 7.0 [mm]
(depending on the sewing equipment
and the subclass)
Value range
01 to 99 [%]
Value range
01 to 14
Value range
-6 to 16
Range
Upper/lower
You can set the active option at the
Technician level Machine
configuration > Mode segment
size.
The s.p.m. option is set at the factory.
The display remains after the thread
has been cut, while counting/
measuring will begin when sewing
starts again.
Value range
0050-2500 [1/min]
(depending on subclass)