Dürkopp Adler 878-M PREMIUM Operating Instructions Manual page 101

Table of Contents

Advertisement

Operating Instructions 878-M PREMIUM - 06.0 - 11/2021
Options for setting the Needle thread tension parameter
Menu item
Setting 1
linear
Needle thread
tension
Value range
00 to 99 [%]
Min. Speed
Value range
0000-4000 [1/min]
(depending on subclass)
Max. Speed
Value range
0000-4000 [1/min]
(depending on subclass)
2. Value
Min. Speed
Value range
On/Off
0000-4000 [1/min]
(depending on subclass)
2. Value On
Min. Speed
Value range
0000-4000 [1/min]
(depending on subclass)
Setting options Sewing foot pressure
Menu item
Setting 1
linear
Sewing foot
pressure
Value range
00 to 20
Min. Speed
Value range
0000-4000 [1/min]
(depending on subclass)
Max. Speed
Value range
0000-4000 [1/min]
(depending on subclass)
Setting 2
Maximum needle thread
tension reached at the
upper speed limit.
Speed at which the
increase in needle thread
tension should start.
Speed up to which the
increase in needle thread
tension should occur.
Speed from which the
nd
2
needle thread tension
should be used.
Speed from which the
nd
2
needle thread tension
should be used.
Setting 2
Maximum sewing foot
pressure reached at the
upper speed limit.
Speed at which the
increase in sewing foot
pressure should start.
Speed up to which the
increase in sewing foot
pressure should occur.
99

Advertisement

Table of Contents
loading

This manual is also suitable for:

878-160722-m878-160725-m878-260722-m

Table of Contents