48

5.4 Manual mode

Fig. 30: Parameters in manual mode
The following table shows the individual symbols (parameters) on
the display and the functions of the keys on the control panel.
When a parameter is selected, its color on the display changes.
When a parameter is changed, its new value is loaded immedi-
ately.
Symbol
Meaning
(depending on the assignment)
Programming
• Press the upper softkey
Quick access function (softkey menu)
• Press the lower softkey,
tion (softkey menu), str. 50.
Program number
Value range: 000 to 999
Program 000 indicates that the controller is in Manual
mode.
• Use
• Use
Or:
• Input the program number directly using the keys
0 to 9 and confirm with OK as required.
This takes you into Automatic mode.
Stitch length
Value range: 0.0 to 7.0 mm (depending on the sewing
equipment)
• Use
• Use
Operating Instructions 878-M PREMIUM - 06.0 - 11/2021
/
to select the Program parameter.
/
to change the program number.
/
to select the Stitch length parameter.
/
to change the stitch length
Settings via the software