Dürkopp Adler 878-M PREMIUM Operating Instructions Manual page 111

Table of Contents

Advertisement

Icon
Parameter
Adjustments for seam end bartack parameters
Bartack at seam end
Number of stitches backwards
Number of stitches forward
Number of bartack sections
A bartack consists of several sections.
If the sewing direction is changed, a new
section is started. The number of sections
in a bartack can be set here.
Stop-Time for direction change
The waiting time at the turning points
(e.g. for a change of sewing direction)
is set at this point. A short waiting time in
milliseconds should ensure consistent
seam quality (ornamental-stitch bartack).
Stitch length default
If this function is active, the same needle
stitch length is used for the bartack as the
one set in Manual mode. If this function is
deactivated, a custom input can be
entered.
Speed in bartack
Operating Instructions 878-M PREMIUM - 06.0 - 11/2021
Settings
Value range
On/Off
Value range
01 to 50
Value range
01 to 50
Value range
01 to 99
Value range
0000–1000 [ms]
On/Off
Stitch length of stitches
forward
Value range
0.1 to 7.0 [mm]
(depending on subclass)
Stitch length of backwards
stitches
Value range
0.1 to 7.0 [mm]
(depending on subclass)
Value range
50 to 2000 [1/min]