Setting The Segment Parameters - Dürkopp Adler 878-M PREMIUM Operating Instructions Manual

Table of Contents

Advertisement

Icon
Parameter
Seam Parameter
Stitch length
Needle thread tension
Upper difference
Lower difference
Sewing foot pressure
Max. Speed
It is possible to reduce the maximum
sewing speed at this point.
The maximum sewing speed can be
set in the software at the Technician
level.
Operating Instructions 878-M PREMIUM - 06.0 - 11/2021
6.5.5
Setting the
There are various options for setting the parameters in the seg-
ment. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
parameters
Segment
Settings
Value range
0.1 to 7.0 [mm]
(depending on the sewing equipment
and the subclass)
Value range
01 to 99 [%]
Value range
-6 to 16
Value range
-6 to 16
Value range
01 to 14
Value range
0050-2500 [1/min]
(depending on subclass)
107

Advertisement

Table of Contents
loading

This manual is also suitable for:

878-160722-m878-160725-m878-260722-m