Figure 20 identifies the slot numbers for base ports and line card ports.
Slot Number 0 for
Slot Number 1 for
Base Ports:
XEM2 Line Card:
port1.0.n
port1.1.n
Figure 20. Slot Numbers for Port Numbering on Stand-alone Switches
You have to include the PORT parameter when identifying individual
ports, and omit it from the last port when specifying ranges.
Here are examples of the PORT parameter in the INTERFACE command
for stand-alone switches. The first example enters the port Interface mode
for base ports 11 and 14:
awplus> enable
awplus# configure terminal
awplus(config)# interface port1.0.11,port1.0.14
This example enters the port Interface mode for base ports 6 to 10:
awplus(config)# interface port1.0.6-1.0.10
This example enters the port Interface mode for ports 4 and 5 on an XEM2
Line Card in the expansion slot:
awplus(config)# interface port1.1.4,port1.1.5
This example enters the port Interface mode for port 6 in the base ports
and port 5 on a line card:
awplus(config)# interface port1.0.6,port1.1.5
For further instructions, refer to the Software Reference for x950 Switch,
AlliedWare Plus Operating System.