Replacing AT-PWR600 AC Power Supplies
This section contains the procedure for removing or replacing AT-PWR600
AC Power Supplies.The following illustrations show the removal of a
power supply from slot PSU A. The procedure is the same for replacing a
power supply in slot PSU B.
Note
Allied Telesis recommends saving a backup copy of the
configuration file in the switch before removing or replacing power
supplies. For instructions, refer to the Software Reference for x950
Switch, AlliedWare Plus Operating System.
To remove power supplies from the switch, perform the following
procedure:
1. Disconnect the AC power cord for the power supply from the AC power
source. Refer to Figure 84.
Figure 84. Disconnecting the AC Power Cord from the Power Source
2. Open the restraining strap on the power cord by pressing down on the
release tab and pulling out the strap. Refer to Figure 85 on page 142.
x950 Series Installation Guide for Stand-alone Switches
141