Bootable Array
To create a bootable array:
1 From the Main menu, select array, press Enter, then press B for
the Bootable function.
2 Select Mark Bootable and press Enter.
Note: Mark Bootable gives boot priority to the array
regardless of the SCSI ID priority.
A
will appear next to the drive ID to indicate it as bootable.
B
Create, Spare, Delete, Rebuild, Verify, Bootable
ID
Type
00
Mirrored (R1)
B
03
Hard Drive
V<Arrow> move cursor, <Enter> accept option, <Esc> exit
Check Point
HostRAID has a check point feature that enables you to exit the
SCSISelect utility when an operation (for example, Verify, or
Rebuild) is in progress. The HostRAID driver will continue the
operation where SCSISelect left off and SCSISelect will continue the
operation where the HostRAID driver left off if an operation was
started from the driver.
Using the SCSISelect Utility to Manage Arrays
Adaptec
SCSISelect(TM)
39320A at slot 03, 00:0F:00
Vendor
Adaptec
Quantum
Utility vX.XX
Product
Size
HostRAID-A
2GB
XP3227W
2GB
Status
Optimal
Free
4-15