Mitsubishi Electric MELSEC-F FX3U-CAN User Manual page 110

Hide thumbs Also See for MELSEC-F FX3U-CAN:
Table of Contents

Advertisement

FX
-CAN User's Manual
3U
Status transition
Power
disabled
9
8
Power
enabled
Command
Shutdown
Switch on
Switch on + enable operation
Disable voltage
Quick stop
Disable operation
Enable operation
Fault reset
Note
• At the following Transition numbers occur a automatic status transition: 0, 1, 13, 14
• Automatic transition to enable operation state after executing SWITCHED ON state functionality.
104
Start
0
Not ready to
switch on
1
15
Switch on
disabled
2
7
10
Ready to
switch on
3
6
Switched on
4
5
11
Operation
Quick stop
enabled
active
16
Bits of the control word
Bit 7
Bit 3
0
X
0
0
0
1
0
X
0
X
0
0
0
1
0 → 1
X
5.10 Application Profile CiA
Number: Transition No.
Fault
13
Fault reaction
active
14
Fault
12
Transition No.
Bit 2
Bit 1
Bit 0
1
1
0
1
1
1
1
1
1
X
0
X
0
1
X
1
1
1
1
1
1
X
X
X
5 Introduction of Functions
®
417 V2.1 for Lift Control Systems
2, 6, 8
3
3 + 4 (Note)
7, 9, 10, 12
7, 10, 11
5
4, 16
15