4. Floor field [High byte in BFM #3002 and #12002]
BFM #3002
BFM #12002
High Byte
Value (hex)
00
01 to FE
FF
5. Door field [Low byte in BFM #3003 and #12003]
This value provides the door number to which the sending virtual device is assigned. The structure of the field
depends on the value of the basic function field.
Basic Function Field
BFM #3001
BFM #12001
Low Byte
Value (hex)
00 to 07
or
0E to FF
08 to 0D
6. Function data field [High byte in BFM #3003 and #12003]
The function data provides the input state of a virtual input.
BFM #3003
BFM #12003
(High Byte)
Bit No.
Bit 8 and 9
Bit 10 to 14
Bit 15
154
Description
Car panel
Panel of floor 1 to 254
Reserved
Door Field
BFM #3003
BFM #12003
Low Byte
Bit No.
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4 to 7
Bit 4 to 7 fixed to OFF (0).
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 9
OFF (0)
Input state
OFF (0)
ON (1)
ON (1)
Reserved
OFF (0): Button or key-button has no locking function
lock
ON (1):
Button or key-button has locking function
Description
Door 1
Door 2
Door 3
Door 4
Source door 1
Source door 2
Source door 3
Source door 4
Destination door 1
Destination door 2
Destination door 3
Destination door 4
Description
Bit 8
Description
OFF (0)
Input state is OFF.
ON (1)
Input state is ON.
OFF (0)
Function is defective
ON (1)
Function is not installed
®
8 CANopen
417 Mode
8.3 Virtual Input/Output Mapping