Mitsubishi Electric MELSEC-F FX3U-CAN User Manual page 163

Hide thumbs Also See for MELSEC-F FX3U-CAN:
Table of Contents

Advertisement

FX
-CAN User's Manual
3U
Basic Function
Field
BFM #3001
BFM #13001
Low Byte Value
(hex)
42
43
43
44
45 to 46
47
48 to 49
4A
4B to 7F
80 to FF
3. Lift field [Low byte in BFM #3002 and #13002]
This value provides the lift number or the group of lifts, to which the output is assigned.
BFM #3002
BFM #13002
Low Byte
BFM #3002
BFM #13002
Bit 0 to 7
Sub-Function Field
BFM #3001
BFM #13001
High Byte Value
(hex)
This sub-function shows the arrow display direction up/down, and the transfer direction display of the car.
Bit
15 ... 14
13
Moving
H0
down
Bit 8 and 9 show the arrow display direction up/down.
OFF (0): Do not display the arrow
ON (1):
Display the arrow
Bit 12 and 13 show the transfer direction display of the car.
OFF (0): Not moving
ON (1):
Moving
00
Used for instruction → all displays off
01
No load
02
Full load
03
Over load
04
Fire
05
Fire brigade service
06
Help is coming
07
Special service
08
Load time
09
Occupied
0A
Out of order
0B
Close door
0C
Case of fire
0D
Hall call disable
0E
Travel to evacuation floor
0F
Travel to fire recall floor
10 to FF
Reserved
This sub-function shows the arrival indication of up/down.
Bit
15 ... 10
9
H0
Down
OFF (0): Not arrived
ON (1):
Arrived
00 to FF
Reserved
00
Switch off speech synthesis on all output panels
01 to FE
Announce floor number 1 to 254
FF
Announce current floor number
00 to FF
Reserved
00
Reserved
01
Hall call enable
02
Lift operational
03 to FF
Reserved
00 to FF
Reserved
00 to FF
Manufacturer-specific
Bit 7
Bit 6
Lift 8
Lift 7
Description
12
11 ... 10
Moving
H0
up
8
Up
Description
Bit 5
Bit 4
Bit 3
Lift 6
Lift 5
Lift 4
®
8 CANopen
417 Mode
8.3 Virtual Input/Output Mapping
9
8
Down
Up
Bit 2
Bit 1
Bit 0
Lift 3
Lift 2
Lift 1
1
2
3
4
5
6
7
8
9