Changing the Hold-down Force
The down force appled by the mddle 3 push rollers can be changed dependng on the wdth and type of meda
used.
When usng the genune Graphtec paper, please set the force of the mddle push roller to "Normal" and the
remanng 2 rollers to "Low" (OFF).
Left-hand push roller
Grt roller
Switching
(1) Lower the meda set lever to rase the push rollers.
(2) Use the push roller hold-down force swtchng lever on the back of the push roller to adjust the center push
roller's hold-down force. It can be set to Normal or Low (OFF).
(3) When the push roller hold-down force swtchng lever s up, t s n Normal mode. When t s down, t's Low
(OFF).
Hold-down force: Normal
CAUTION
Hold-down force can not be swtched for sde push rollers.
Supplement
Swtch the hold-down force as necessary for dfferent types of meda.
Low (OFF)
Normal
Low (OFF)
Push roller
Meda sensor
Lever
Hold-down force: Low (OFF)
Rght-hand push roller
Lever
2-18