Table B-1. Library error codes (continued)
Code (H)
Description
Accessor error #2.
Forward FWD position (PP2)
error (Accessor origin
00B9
detected or FWD not
detected). Suspect the P
origin sensor, FWD sensor, or
P motor.
Accessor error #3.
PUT/GET/bar code reader
position
(PP4/PP5/PPBF/PPBR)
00BA
error (Accessor origin or
FWD detected, or cell full).
Suspect the P origin sensor,
FWD sensor, or P motor.
During initialization, the
Accessor origin could not be
00BC
detected. Suspect the P origin
sensor, FWD sensor, or P
motor.
During Accessor movement,
the movement stop condition
00BD
detected. Suspect the P
encoder sensor or P motor.
No gap condition detected at
the completion of Accessor
operation. Suspect the
00BF
centering sensor, P origin
sensor, FWD sensor, or P
motor.
Accessor operation disabled
because a cartridge magazine
00C0
was removed. Suspect the
magazine set sensor.
Centering calibration error
#1.
During centering calibration,
00C8
centering sensor OFF
condition could not be
detected. Suspect the
centering sensor or P motor.
Centering calibration error
#2.
During centering calibration,
centering sensor ON
00C9
condition could not be
detected. Suspect the
centering sensor, X motor, or
P motor.
Panel Indication
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
CHK 00B9
• If the problem persists, see "Contacting IBM
Technical Support" on page 7-1.
CHK 00BA
CHK 00BC
CHK 00BD
CHK 00BF
1. Confirm the magazine is closed.
2. Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
CHK 00C0
• If the problem persists, see "Contacting IBM
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
CHK 00C8
• If the problem persists, see "Contacting IBM
Technical Support" on page 7-1.
CHK 00C9
Action Required
before resuming normal library operations.
Technical Support" on page 7-1.
Appendix B. Error Codes