IBM TS2900 Setup, Operator, And Service Manual page 197

System storage tape autoloader
Hide thumbs Also See for TS2900:
Table of Contents

Advertisement

Table B-1. Library error codes (continued)
Code (H)
Description
Drive does not enter
MOUNT state within 200
007D
seconds of a PUT command.
Suspect the drive or X motor.
Drive does not enter SET
state within 3 seconds of a
007E
PUT command. Suspect the
drive or X motor.
Drive I/F or connection error
occurs during a PUT
007F
operation or GET operation.
Suspect the drive.
X movement error #1.
During X movement, the
target stop position's origin
0080
sensor error detected.
Suspect the X origin sensor or
X motor.
X movement error #2.
During X movement, a motor
0081
sync error detected. Suspect
the X encoder sensor or X
motor.
X movement error #3.
During initialization, a motor
0082
sync error detected. Suspect
the X encoder sensor or X
motor.
During an eject operation or
move operation (to a storage
position), the X origin sensor
0083
could not be detected.
Suspect the X origin sensor or
X motor.
During initialization, the X
origin position could not be
0084
detected. Suspect the X origin
sensor or X motor.
X calibration error #1.
During X calibration,
centering sensor OFF
0088
condition could not be
detected. Suspect the
centering sensor or X motor.
X calibration error #2.
During X calibration,
0089
centering sensor ON
condition could not be
detected.
Panel Indication
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
CHK 007D
before resuming normal library operations.
• If the problem persists, see "Contacting IBM
Technical Support" on page 7-1.
CHK 007E
1. Reseat all cables. See "Reseating Cables" on
page 6-10.
2. Cycle the power supply and try again.
CHK 007F
• If the problem is corrected, run Library Verify
• If the problem persists, see "Contacting IBM
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
before resuming normal library operations.
CHK 0080
• If the problem persists, see "Contacting IBM
Technical Support" on page 7-1.
CHK 0081
CHK 0082
CHK 0083
CHK 0084
CHK 0088
CHK 0089
Action Required
before resuming normal library operations.
Technical Support" on page 7-1.
Appendix B. Error Codes
B-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

3572