Table B-1. Library error codes (continued)
Code (H)
Description
LDI I/F error.
002C
ACK IU event timeout
detected.
LDI I/F error.
002D
Response IU event timeout
detected.
LDI I/F error.
002E
Transfer Ready IU event
timeout detected.
LDI I/F error.
002F
Undefined error detected.
A drive media error detected
0040
upon insertion.
A drive load timeout error
0042
detected upon insertion.
Response acknowledge error
received from bar code
0053
reader. Suspect the bar code
reader cable connection.
Receive data checksum error
received from bar code
0056
reader. Suspect the bar code
reader cable connection.
Invalid data received from
bar code reader. Suspect the
0057
bar code reader cable
connection.
A bar code reader read-error
0058
detected. Suspect the bar
code reader cable connection.
A bar code reader FLASH
control error detected.
0059
Suspect the bar code reader
cable connection.
A bar code reader
diagnostics error detected.
005A
Suspect the bar code reader
cable connection.
Panel Indication
Cycle the power supply and try again.
-
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see "Contacting IBM
Technical Support" on page 7-1.
-
-
-
1. Verify that the cartridge is compatible with the
drive in your library. See "Media" on page 1-8.
2. Verify that the cartridge is not write-protected.
See "Write-Protect Switch" on page 5-7.
3. If it is a cleaning cartridge, verify that the
cartridge has not expired. See "Viewing the
CHK 0040
Library Map" on page 4-16.
4. Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
• If the problem persists, see "Contacting IBM
Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
CHK 0042
before resuming normal library operations.
• If the problem persists, see "Contacting IBM
Technical Support" on page 7-1.
1. Initiate an inventory. See "Conducting a Library
Inventory" on page 4-6 (Operator Panel) or
CHK 0053
"Conducting a Library Inventory" on page 4-19
(Web User Interface).
2. Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
CHK 0056
• If the problem persists, see "Contacting IBM
CHK 0057
CHK 0058
CHK 0059
CHK 005A
Action Required
before resuming normal library operations.
Technical Support" on page 7-1.
before resuming normal library operations.
Technical Support" on page 7-1.