IBM TS2900 Setup, Operator, And Service Manual page 194

System storage tape autoloader
Hide thumbs Also See for TS2900:
Table of Contents

Advertisement

Table B-1. Library error codes (continued)
Code (H)
Description
Information acquisition from
0010
the DHCP server failed.
Time acquisition from the
0011
NTP server failed.
LDI I/F error.
0020
Transmit data abnormality
detected (NAK reception).
LDI I/F error.
0021
Receive timeout detected
(ACK/NAK reception).
LDI I/F error.
0022
Response packet reception
timeout detected.
LDI I/F error.
0023
ENQ receive timeout
detected.
LDI I/F error.
0024
Receive data abnormality
detected.
Encryption command
0029
terminates unsuccessfully.
Commands to the Encryption
002A
Key Manager over the retry
limit.
Commands to the encryption
002B
capable drive over the retry
limit.
B-2
TS2900 Tape Autoloader Setup, Operator, and Service Guide
Panel Indication
1. Observe LEDs. See "Interpreting Front Panel
LEDs" on page 6-8.
2. Confirm the DHCP server settings.
3. Reseat all cables. See "Reseating Cables" on
page 6-10.
-
4. Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
• If the problem persists, see "Contacting IBM
1. Observe LEDs. See "Interpreting Front Panel
LEDs" on page 6-8.
2. Confirm the time server settings.
3. Reseat all cables. See "Reseating Cables" on
page 6-10.
-
4. Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
• If the problem persists, see "Contacting IBM
1. Observe LEDs. See "Interpreting Front Panel
LEDs" on page 6-8.
-
2. Reseat all cables. See "Reseating Cables" on
page 6-10.
3. Cycle the power supply and try again.
-
• If the problem is corrected, run Library Verify
• If the problem persists, see "Contacting IBM
-
-
-
1. Confirm the Encryption Key Manager settings.
-
2. Reseat all cables. See "Reseating Cables" on
page 6-10.
3. Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
-
• If the problem persists, see "Contacting IBM
1. Reseat all cables. See "Reseating Cables" on
page 6-10.
2. Cycle the power supply and try again.
-
• If the problem is corrected, run Library Verify
• If the problem persists, see "Contacting IBM
Action Required
before resuming normal library operations.
Technical Support" on page 7-1.
before resuming normal library operations.
Technical Support" on page 7-1.
before resuming normal library operations.
Technical Support" on page 7-1.
before resuming normal library operations.
Technical Support" on page 7-1.
before resuming normal library operations.
Technical Support" on page 7-1.

Advertisement

Table of Contents
loading

This manual is also suitable for:

3572

Table of Contents