Table B-1. Library error codes (continued)
Code (H)
Description
2
I
C I/F error.
Invalid signal (NAK)
005D
detected. Suspect the bar
code reader cable connection.
2
I
C I/F error.
Bus arbitration lost error
005E
detected. Suspect the bar
code reader cable connection.
2
I
C I/F error.
Ready condition does not
005F
occur. Suspect the bar code
reader cable connection.
Calibration failed because the
0070
Accessor contains media.
Suspect the centering sensor.
Calibration failed due to an
0071
empty magazine. Suspect the
magazine set sensor.
Calibration measurement
invalid data error. Suspect
0072
the centering sensor, X motor,
or P motor.
GET, centering check, or bar
code reader read operation
0074
failed because the Accessor
contains media. Suspect the
centering sensor.
PUT operation failed because
the Accessor contains no
0075
media. Suspect the centering
sensor.
Drive does not enter EJECT
state (and media not ejected)
007C
within 200 seconds of a GET
command. Suspect the drive.
B-4
TS2900 Tape Autoloader Setup, Operator, and Service Guide
Panel Indication
1. Initiate an inventory. See "Conducting a Library
Inventory" on page 4-6 (Operator Panel) or
CHK 005D
"Conducting a Library Inventory" on page 4-19
(Web User Interface).
2. Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
CHK 005E
• If the problem persists, see "Contacting IBM
CHK 005F
1. Attempt to unload the cartridge from the
Accessor. See "Moving Cartridges" on page 4-5
(Operator Panel) or "Moving Cartridges" on
page 4-17 (Web User Interface).
2. Cycle the power supply and try again.
CHK 0070
• If the problem is corrected, run Library Verify
• If the problem persists, see "Contacting IBM
Cycle the power supply and try again.
CHK 0071
• If the problem is corrected, run Library Verify
before resuming normal library operations.
• If the problem persists, see "Contacting IBM
Technical Support" on page 7-1.
CHK 0072
CHK 0074
CHK 0075
1. If the cartridge does not eject, try to unload the
cartridge from the drive using the Operator
Panel (Commands → Unload) or the Web User
Interface (Manage Library → Unload). Move
the cartridge from the drive to the I/O Station.
Remove the cartridge from the library and
CHK 007C
inspect for damage and replace, if necessary.
2. Cycle the power supply and try again.
• If the problem is corrected, run Library Verify
• If the problem persists, see "Contacting IBM
Action Required
before resuming normal library operations.
Technical Support" on page 7-1.
before resuming normal library operations.
Technical Support" on page 7-1.
before resuming normal library operations.
Technical Support" on page 7-1.