2.5.4. Data Acquisition Inputs
The Data Acquisition ± input is used for the hardware Data Acquisition feature. The delay time through the
high-speed opto devices is 50 nsec (typical). The high-speed input is scaled for 5-24 VDC input and can be
used with sourcing or sinking drivers.
Table 2-25:
Data Acquisition Input Pins on the PSO Connector
Pin # Description
1
Data Acquisition +
14
Data Acquisition -
Table 2-26:
Data Acquisition Opto-Isolator Input Specifications
Specification (HCPL-0630)
Input Voltage
Input Current
www.aerotech.com
Chapter 2: Installation and Configuration
Figure 2-29:
Data Acquisition Input Schematic
In/Out/Bi
Value
5-24 V
10 mA
Input
Input