Table 12-6 Dry Contact Input/Output Mapping - Raisecom RC3000-15 Hardware Description

Table of Contents

Advertisement

Raisecom
RC3000-15 (P100R001) Hardware Description
Interface
2
Input/Output mapping
The dry contact controls output of on/off values by collecting input of them. When the input
switch is OFF, the COM pin and CLOSE pin of the output interface are connected. When the
input switch is ON, the COM pin and OPEN pin of the output interface are connected, as
listed in Table 12-6.
The NMS displays output status of dry contact. When the dry contact input control mode is
network management control, you can control output status of dry contact through the NMS
or CLI.

Table 12-6 Dry contact input/output mapping

Input
Status
OFF
The input switch is off, and no
alarms are input.
ON
The input switch is on, and
some alarm is input.
PIN
10
OUT
11
OUT
12
OUT
1
OUT
2
OUT
3
OUT
4
OUT
5
OUT
6
OUT
7
OUT
8
OUT
9
OUT
10
OUT
11
OUT
12
OUT
Description
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
I/O
No. 4 channel OPEN pin
No. 4 channel COM pin
No. 4 channel CLOSE pin
No. 5 channel OPEN pin
No. 5 channel COM pin
No. 5 channel CLOSE pin
No. 6 channel OPEN pin
No. 6 channel COM pin
No. 6 channel CLOSE pin
No. 7 channel OPEN pin
No. 7 channel COM pin
No. 7 channel CLOSE pin
No. 8 channel OPEN pin
No. 8 channel COM pin
No. 8 channel CLOSE pin
Output
Status
Contact
The COM pin and CLOSE
Normal
pin of the Phoenix terminal
are connected.
Contact
The COM pin and OPEN pin
Operated
of the Phoenix terminal are
connected.
12 Telecontrol service cards
PIN definition
Description
NMS
display
Contact
Normal
Contact
Operated
180