  • Page 1 Raisecom Technology Co., Ltd RC3000 PCM Multi-Service Multiplexer User Manual Raisecom Technology Co., Ltd £ ¨ 9/2005£ ©...
  • Page 2: Cautions

    Raisecom Technology Co., Ltd 1. Cautions Please read the following notices carefully before installing and using this device, Raisecom does not respond to any loss caused by violating safety notices. RC3000 is integrated device that has precise elements, please avoid violent shakes and impacts, and do not disassemble or maintain the device yourself.
  • Page 3: Table Of Contents

    Raisecom Technology Co., Ltd Contents Cautions ......................1 Overview......................7 2.1. Introduction ....................7 2.2. Main features: ..................7 Application examples:..................9 3.1. Traditional PCM application ..............9 3.2. Automatic ADM application ..............9 3.3. Multi devices ADM application..............10 3.4.
  • Page 4 Raisecom Technology Co., Ltd 6.2. Front panel explanation:................. 24 6.2.1. Globle indicator lights: ..............24 6.2.2. Indicator lights of line-board: ............24 6.2.3. Optical interface alarm indicator lights:.......... 24 6.2.4. E1 line alarm indicator lights: ............25 6.2.5. Definition of mute, DIP-switches and interfaces: ......25 6.3.
  • Page 5 Raisecom Technology Co., Ltd 8.3. Installation ....................47 8.3.1. Device fixing:................. 47 8.3.2. Cabble connection ................ 47 8.3.3. Powered on: .................. 48 Q & A ........................ 49 9.1. SYS is ON....................49 9.2. Alarms of E1 interface................49 9.3. Cross connection cannot communicate normally ........49 9.4.
  • Page 6 Raisecom Technology Co., Ltd 10.9.3. Line-Board set................64 10.9.4. E1 set ..................65 10.9.5. E1 Clock Set ................65 10.9.6. Net Topology Set ................. 65 10.9.7. Alarm Sound Set ................. 68 10.9.8. User Board Set................68 10.9.9. DCD and RTS of V35V24 Board with Alarm Set ......69 10.10.
  • Page 7 Raisecom Technology Co., Ltd 10.16.2. Create Group Cross ..............79 10.16.3. Delete Group Cross ..............80 10.17. Operate menu..................81 10.17.1. System Reset................81 10.17.2. Mute ..................81 10.17.3. Clear All Set ................81 10.17.4. Clear Cross Set................. 82 10.17.5. Save Set Info................82 10.17.6.
  • Page 8: Overview

    Raisecom Technology Co., Ltd 2. Overview 2.1. Introduction RC3000 is a PCM multi-service multiplexer that uses both traditional and modern technologies, and can provide a high reliable access at a low cost along with multi functions, easy application and maintenance.
  • Page 9 Raisecom Technology Co., Ltd Strong network management function: both assistant network management channel and network management cascade are available to manage whole network of RC3000 devices.
  • Page 10: Application Examples

    Raisecom Technology Co., Ltd 3. Application examples: 3.1. Traditional PCM application Figure 1 The default factory status of RC3000 is without any configuration. All user-boards support automatic recognition and voice channel allocation. In figure 1, the same extension slots in the two devices use the same timeslots. In simple application, with proper user-board the devices can start to work without any configuration.
  • Page 11: Multi Devices Adm Application

    Raisecom Technology Co., Ltd RC3000-2E1 (ADM) will connect the same channels (unused) of 1E1 and 2E1 automatically. That is to say, when there is no user-board all the channels in 1E1 will be cross connected with those of 2E1; in this case the device has ADM function. The...
  • Page 12: Point-To-Multipoint Star Topology Application

    Raisecom Technology Co., Ltd In this application, voice channels in local device can be alloted to remote RC3000s, and voice channels of remote RC3000s can be cross connected too. So multi services access can be realized. 3.4. Point-to-multipoint star topology application...
  • Page 13: Device Type And User-Board Explanation

    Raisecom Technology Co., Ltd 4. Device type and user-board explanation 4.1. Device type explanation: Explanation of device type: RC3000-XXX-XX-XX AC Device name: multi-service multiplexer Line-board Assistant interface type of optical line-board Optical interface type of optical line-board Power supply type: AC or DC...
  • Page 14: User-Board Type Explanation

    Raisecom Technology Co., Ltd RC3000-OPT-S1FC Single-mode Dual-fiber 1310,DFC, 0~25Km RC3000-OPT-M Single-mode Dual-fiber 1310,DSC, 0~2Km RC3000-OPT-AS1 Single-mode Dual-fiber 1310,DSC, with ALS function, 0~25Km RC3000-OPT-AS2 Single-mode Dual-fiber 1310,DSC, with ALS function, 10~50Km Note: device types in the shadow are customized products. For power supply type (after the device type), voltage range of AC is 85 to 265V and DC is -36 to -72 V ALS: Automatic Leaser Shutdown/Reduction.
  • Page 15 Raisecom Technology Co., Ltd RC3000-SUB-D422 RS422 serial data user-board 8 channels, unconfigurable RC3000-SUB-DMT Magneto telephone user-board 8 channels, unconfigurable RC3000-SUB-DSR FXS user-board with polarity 8 channels, unconfigurable reversal function...
  • Page 16: Parameters

    Raisecom Technology Co., Ltd 5. Parameters 5.1. Line-board parameters: 5.1.1. E1 interface parameters: Standard baud rate: 2048Kbps±50ppm Interface coding: HDB3 Interface impedance: 75Ω unbalanced£ © ,120Ω balanced£ © Electric feathers: ITU-T G.703 compliant Frame format: ITU-T G.704 compliant Jitter: ITU-T G.823 compliant...
  • Page 17: Ethernet Interface Parameters

    Raisecom Technology Co., Ltd RC3000-OPT-SS23 SC/PC T1310/R1550 -5 ~ 0 RC3000-OPT-SS25 SC/PC T1550/R1310 -5 ~ 0 RC3000-OPT-S1FC DFC 1310 -15 ~ 0 ~ 25 1310 -15 ~ 0 ~ 25 RC3000-OPT-M 1310 -15 ~ 0 ~ 25 RC3000-OPT-AS1 1310 -5 ~ 0 RC3000-OPT-AS2 Note: device types in the shadow are customized products.
  • Page 18: Interface Standard Of Fxo Voice Relay User-Board (Rc3000-Sub-Do)

    Raisecom Technology Co., Ltd Return loss: 30-40 db Balance: 60-70 db Common-Mode Rejection Ratio: 60-70 db Power Supply Rejection Ratio: Vcc: 30 db Vbat: 30 db Idle channel noise: 75 db 5.2.2. Interface standard of FXO voice relay user-board (RC3000-SUB-DO): Ring detect voltage: ≥35 V...
  • Page 19: Interface Standard Of E&M 4 Audio Relay User-Board (Rc3000-Sub-Dm4)

    Raisecom Technology Co., Ltd Return loss: 20 db Maximum voltage of common-mode: 300 V Common-Mode Rejection Ratio: >55 db Power supply Rejection Ratio: 30 db Idle channel noise: 60 db Note: AD gain and DA gain are adjustable according to user’s requirement 5.2.4.
  • Page 20: Interface Standard Of Ethernet Data User-Board (Rc3000-Sub-Deth)

    Raisecom Technology Co., Ltd Interface rate: N×64Kbps£ ¨ N=1-31£ © 5.2.7. Interface standard of Ethernet data user-board (RC3000-SUB-DETH): RJ-45 interface of UTP, the longest tansmission distance of 5-category cable is 100m. Comply with IEEE 802.3 standard, 10/100M auto negotiation, full/half duplex auto negotiation.
  • Page 21: Interface Standard Of Fxs User-Board With Polarity Reversal Function

    Raisecom Technology Co., Ltd Ring not detect voltage: ≤15 V 2W input impedance: normal and not ring status: 600Ω 2W input impedance: ring or abnormal status: 1000K Ω Gain from 2W to 4W: 0±0.5 db Frequency characteristic from 2W to 4w: 0±0.2 db...
  • Page 22: Environment Requirement

    Raisecom Technology Co., Ltd 5.4. Environment requirement Temperature:0 ~ 50¡ æ Relative humidity:≤90%£ ¨ 25 ¡ æ noncondensing £ ©...
  • Page 23: Structure And Indicator Lights

    Raisecom Technology Co., Ltd 6. Structure and indicator lights 6.1. Fundamental structure: Fundamental structure of RC3000 is as follows: System NM channel information & MPU control module alarm Memory module RC7850 module Line-board User-board Cross-matrix and interface interface information processing...
  • Page 24 Raisecom Technology Co., Ltd find problems in time. MPU control modue: this module is the system controller; once powered on it will check the data saved in the memory, if the data is valid MPU will configure device according to saved data, otherwise it will generate default data according to hardware status and set the default data to RC7850 for cross connect, and than system will work normally.
  • Page 25: Front Panel Explanation

    Raisecom Technology Co., Ltd 6.2. Front panel explanation: Front view: Figure 17 6.2.1. Globle indicator lights: SYS£ ¨ green£ © : Indicates system work status. Flicking: system works normal. ON: 1 CUP works abnormal; 2 system configuration error or the following problems: 1£...
  • Page 26: E1 Line Alarm Indicator Lights

    A RJ45 connector to connect PC and RC3000 device for Hyper Terminal configuration (through the cable offered by Raisecom, and please plug the cable in RJ45 connector first and then the DB9 serial interface connector on PC, this will protect the serial interface), set the first bit of DIP-switches ON, startup Hyper Terminal and then you can configure the device.
  • Page 27: Rear Panel Explanation

    Raisecom Technology Co., Ltd Hyper Terminal. This operation will not affect the whole network management but only shielded that device for a while. Second bit: PC network management access. When this RC3000 is network management access device or network management is connected to its LINK UP interface, set this bit ON, and MCU will receive the network management information from LINK UP interface.
  • Page 28: Line-Board Interface

    Raisecom Technology Co., Ltd All user-boards support hot-swap and this operation will not affect device work status. 6.3.2. Line-board interface: There is one line-board slot for each RC3000 and the device cannot work without line-board. You must confirm the type of line-board when ordering because it is fixed and not hot-swap: 1.
  • Page 29: Function & Application

    Raisecom Technology Co., Ltd 7. Function & Application 7.1. Function and application explanation of RC3000: 7.1.1. Factory default configuration There is only hardware version of a new RC3000 and without any cross configuration. 7.1.2. Start self-check RC3000 will check all configurations when powered on, including: system configuration information, cross connect configuration information, line-board information and user-board information.
  • Page 30: Clock Switch Explanation

    Raisecom Technology Co., Ltd RC3000-2E1: single E1 direction. RC3000-2E1 (ADM): dual-E1 direction. RC3000-4E1: single E1 direction. 7.1.4. Clock switch explanation In factory default status, clock mode of RC3000 is slave clock (trace first E1); the device can switch clock by itself in clock auto-switch mode according to practice so that all devices can work under a uniform clock.
  • Page 31: Explanation Of System Configuration And Cross Connect Configuration

    Raisecom Technology Co., Ltd 1E1 and 2E1. RC will first use valid cross connect configuration information saved in memory, and erase invalid configuarion information automaticly. Rules for cross connection are as follows: a. All configurations will be refreshed if the line-board is changed and all saved cross connect information is invalid.
  • Page 32: Network Management Channel Explanation

    Raisecom Technology Co., Ltd e. Remote alarm indicator f. Signal loss of multiframe alignment alarm g. CRC loss of multiframe alignment alarm There is no f and g alarm on device panel and you can get these alarm information through network management or Hyper Terminal.
  • Page 33: Interface Definitions

    Raisecom Technology Co., Ltd In this topology the lines between each RC3000 are assistant network management channels, and for normal network management there must be network management topology configuration as follows: RC3000 A: double E1 channel direction RC3000 B: single E1 channel direction...
  • Page 34 Raisecom Technology Co., Ltd 1 2 3 4 5 6 7 8 Pin number Signal Explanation Rx of RC3000 Tx of RC3000 Ground of RC3000 Figure 21 b.LINK UP definition: Network management interface LINK UP is RC45 interface and standard RC232 voltage:...
  • Page 35: Rc3000-Sub-Ds User Voice Card Explanation

    Raisecom Technology Co., Ltd 7.2. RC3000-SUB-DS user voice card explanation FXS is a user voice card with feed voltage and feed ring and can be connected to exterior line interface of FBX. There are 8 channels of a FXS and the channel number is decided by hardware, unchangeable.
  • Page 36: Rc3000-Sub-Do Voice Relay Card Explanation

    Raisecom Technology Co., Ltd 7.3. RC3000-SUB-DO voice relay card explanation FXO is a voice relay card for the relay of FBX voice channel and is connected to output interface of FBX voice channel. There are 8 channels of a FXO and the channel number is decided by hardware, unchangeable.
  • Page 37: Rc3000-Sub-Dso User-Board Explanation

    Raisecom Technology Co., Ltd 7.4. RC3000-SUB-DSO user-board explanation RC3000-SUB-DSO is a customized hybrid card of FXS and FXO, there can be N FXS interfaces and M FSO interfaces (M, N can be 0, and M+N=8). There totally 8 channels decided by hardware, unchangeable. Two RJ45 interfaces make up of the 8 channels (each RJ45 interface has four channnels).
  • Page 38: Rc3000-Sub-Dm4 Audio Relay Card Explanation

    Raisecom Technology Co., Ltd Fundamental structure of RC3000-SUB-DM2: Voice channel control module interface Multiplexing module Voice input & Voice channel Multiplexing & balance output interface module Signal input & Multiplexing output process module Voice D/A converter Control Control bus channel output...
  • Page 39: Rc3000-Sub-Dv35 User-Board Explanation

    Raisecom Technology Co., Ltd Fundamental structure of: Voice channel control module interface Multiplexing module Voice channel Voice input & interface Multiplexing output Voice D/A converter Signal input & Multiplexing output process module Control Control bus channel output Control bus process E &...
  • Page 40: V35 Interface Definition

    Raisecom Technology Co., Ltd of each) to access 4 user groups (user E1), and we refer these 4 user E1 as cross groups 5, 6, 7 and 8. The first user E1 is a main cross group and channels of this cross group will be distributed to user cards by default.
  • Page 41: V35 Data Card Configuration Explanation

    Raisecom Technology Co., Ltd Indicatore lights are all green: TD: V35 data Tx indicator light RD: V35 data Rx indicator light LP_STA: loop indicator light. ON there is local loop PAT_OK: In normal work status is OFF. Do the RCR check: ON normal...
  • Page 42: Rc3000-Sub-Deth User-Board Explanation

    Raisecom Technology Co., Ltd 7.8. RC3000-SUB-DETH user-board explanation 7.8.1. Rules of channel distribution: RC3000-SUB-DETH is an Ethernet data user card with a 10BaseT interface, and please refer to configuration rules of RC3000-SUB-DV35 user card. 7.8.2. Ethernet interface definition Ethernet interface uses RJ45 connector and can realize MDI & MDIX cable as following...
  • Page 43: Rc3000-Sub-D422 User-Board Explanation

    Raisecom Technology Co., Ltd interface is as follows: Channel RJ45-1 RJ45-1 RJ45-2 RJ45-2 Pins 2RD,3TD,1,4GND 6RD,7TD,5,8GND 2RD,3TD,1,4GND 6RD,7TD,5,8GND Channel 5 RJ45-3 RJ45-3 RJ45-4 RJ45-4 Pins 2RD,3TD,1,4GND 6RD,7TD,5,8GND 2RD,3TD,1,4GND 6RD,7TD,5,8GND Note: 2RD is the input of RS232 Rx data, 3TD is the output of Tx data and 4GND is the ground.
  • Page 44: Rc3000-Sub-Dmt User-Board Explantion

    Raisecom Technology Co., Ltd 7.11. RC3000-SUB-DMT user-board explantion RC3000-SUB-DMT is a magneto telephone interface card and can transimit magneto telephone calls (hot-wire magneto telephone). There are 8 channels whitch is decided by hardware, unchangeable. Two RC45 connectors make up of the 8 channels and each RJ45 connector has four channels.
  • Page 45: Rc3000-Sub-Dsr User-Board Explanation

    Raisecom Technology Co., Ltd 7.12. RC3000-SUB-DSR user-board explanation RC3000-SUB-DSR is a phone interface card with polarity reversal function. There are 8 channels which are decided by hardware, unchangeable. Two RC45 connectors make up of the 8 channels and each RJ45 connector has four channels. And the definition of...
  • Page 46: Rc3000-Sub-Opt-Fe Explanation

    Raisecom Technology Co., Ltd 7.13. RC3000-SUB-OPT-FE explanation Optical line-board can communicate with main board and its initial value can be set through DIP switches. There are 2 banks of 8-bit DIP switches and definitions ard as follows: Switch Definition Value...
  • Page 47 Raisecom Technology Co., Ltd through DIP switches. There are 3 banks of 8-bit DIP switches and definitions ard as follows: Switch Definition Value Explanation FFFF FFFN FFNF FFNN SS13 Optical FNFF SS15 module FNFN SS23 type FNNF SS25 FNNN S1FC...
  • Page 48: Installation & Verifying

    Raisecom Technology Co., Ltd 8. Installation & verifying 8.1. Check when you first open the box Check whether the type of device, spare parts and number are same with that of packing list. Make sure the device appearance is in excellent condition. There must be drying process if the device has been damp.
  • Page 49: Powered On

    Raisecom Technology Co., Ltd offered, and when you need to transfer balanced interfaces to unbalanced ones RC909-4E1 of Raisecom is available. c. Optical interface: SC connector is for optical interface. And if you are not sure of Rx & Tx direction, please connect the connector before device powered on.
  • Page 50: Sys Is On

    Raisecom Technology Co., Ltd 9. Q & A 9.1. SYS is ON When there are alarms SYS will be ON. You can check the alarm information through network management or Hyper Terminal to confirm why the buzzer buzzes: a. Communication failure with user card.
  • Page 51: Abnormal

    Raisecom Technology Co., Ltd 9.4. There is no alarm but voice channel is discontinuous or communication is abnormal Generally asynchronism of multiframe causes this phenomenon, check whether there is loss of multiframe of RC3000 E1 interface or CRC loss of multiframe. If there is loss of multiframe, the followings can resolve this problem: a.
  • Page 52: Device Cannot Be Configured Through Console

    9.8. Memory information loss If the information saved in memory lost after RC3000 running for some time, check whether EEPROM can save data normally, if not, bring the device back to Raisecom for maintenance. 9.9. Display of device is abnormal When RC3000 cannot display alarms correctly, check the followings: a.
  • Page 53: Appendix A: How To Use Hyper Terminal To Configure Rc3000

    Raisecom Technology Co., Ltd Appendix A: How to use Hyper Terminal to configure RC3000 10.1. Enter Use the affixed CONSOLE cable to connect CONSOLE interface (RJ45) of RC3000 with PC serial interface (DB9), before connecting make sure that both RC3000 and PC have grounding protection;...
  • Page 54: Input The Password

    Now press ENTER to start configure RC3000 through Hyper Terminal. 10.2. Input the password Before starting to configure the device you need to input the password (default password is raisecom), the prompt is: Please input password and click Enter Password: When enter the password there will be a for every input character.
  • Page 55: Main Menu

    Raisecom Technology Co., Ltd 10.3. Main menu: If the password is right, you can start to operate: Welcome to use Raisecom Communication Device 1.Device Set Query 2.Cross Set Query 3.State Info Query 4.Alarm Query 5.Set 6.Operate 7.Version 8.Console Set 9.Quit...
  • Page 56: Line-Board Information (Ram)

    Raisecom Technology Co., Ltd 10.4.2. Line-Board information (RAM): In device set query menu press number key 2, and then there will be device Line-Board information: Real information: Line-Board Type:2E1 Board (Line-Board card name) Device Query Command:1-8, Menu Display:M, Return:Q Command: There will be Line-Board name for each Line-Board card.
  • Page 57: E1 Using And Mode Information

    Raisecom Technology Co., Ltd 10.4.4. E1 using and mode information: Indevice set query menu press number key 4, and there will be E1 using and mode information: First Second Third Fourth Real information: Use: 1=Using Mode: 1=PCM31 Mask: 1=Mask EEPROM Set:...
  • Page 58: E1 Alarm Mask Information

    Raisecom Technology Co., Ltd Net topology: Single E1 Direction Double E1 Dircetion Three E1 Dircetion Four E1 Dircetion Net Using Time Slot: 0 Time Slot 1 Time Slot CRC transmit: eanble disable 10.4.6. E1 Alarm Mask information: Indevice set query menu press number key 6, and there will be E1 Alarm Mask...
  • Page 59 Raisecom Technology Co., Ltd Channel:Main Channel Local Loopback:Loopback Remote Loopback:No Loopback Error Code Test:Disable 7235 Auto Adjust Phase:Enable Adjust Receive Phase:Enable(Clock Down) DTR State:1(Unready) RTS State:1(Unready) DCD State:0(Ready) CTS State:0(Ready) Note: parameters of phase adjustment: positive and negative; Channel: main channel & Single channel Loopback Set: No Loopback &...
  • Page 60: User-Board Information (Eeprom)

    Raisecom Technology Co., Ltd Signal:Exist Signal In:Original Signal Out:Original Signal Bit(D7:D0):A A A A A A A A Device Query Command:1-8, Menu Display:M, Return:Q Command: 10.4.8. User-Board information (EEPROM) Device Set Query menu press number key 8 you can get the same information saved in EEPROM as User-Board information (RAM) 10.5.
  • Page 61: Four User Cross Query (Ram)

    Raisecom Technology Co., Ltd 10.5.2. Four User Cross Query (RAM) In Cross Set Query menu, press number key 2 and there will be the following information: Input Group No. (1-4, Esc=Cancel): Enter group number 1, cross connection of the first E1 will be displayed:...
  • Page 62: Four User Cross Query (Eeprom)

    Raisecom Technology Co., Ltd indicates there is no cross connection. Address indication: result of row number plus column number is the channel number. For example: £ ¨ 5 17£ © ,the address is 16+1=17 that is to say the data in this cell is the cross...
  • Page 63: Receive State Query

    Raisecom Technology Co., Ltd 10.6.1. Receive State Query In state information query menu press number key 1 there will be the following information: Input Group No.(1-4, Esc=Cancel): Enter group number 1, there will receive signal status information: First Group Receive State...
  • Page 64: System Alarm

    Raisecom Technology Co., Ltd 2E1 Alarm:No Alarm Alarm Query Command:1-2, Menu Display:M, Return:Q Command: Note: E1 interface alarms include: LOS, AIS, LOF, RAL, LOMF, CRC and CRC LOMF Optical interface alarms include: Optical LOS, Frame LOF , E-3 ERROR and E-6 ERROR Alarms include: E1 interface alarms and line-board alarms.
  • Page 65: Id Set

    Raisecom Technology Co., Ltd 10.9.1. ID set In system set menu press number key 1 to configure device ID: DeviceID=2 Input Device ID(0-255): The first row is device present ID and the second row is for user configuring a new ID.
  • Page 66: E1 Set

    Raisecom Technology Co., Ltd 10.9.4. E1 set In system set menu press number key 4 to configure E1 interface and the menu will be: 1.Use Set 2.Mode Set 3.Mask Set 4.CRC Set E1 Set Command:1-4, Menu Display:M, Return:Q Command: The explanation of each command is available in 8.10 E1 set 10.9.5.
  • Page 67 Raisecom Technology Co., Ltd panel, all RC3000 devices can be managed. To realize whole network management the following rules must be obeyed: If time slot 0 is network management channel, the maximum rate of serial data is 2400bps, otherwise there will be error codes.
  • Page 68 Raisecom Technology Co., Ltd RC3000-2E1 Device 2 RC3000-2E1 RC3000-2E1 Device 1 Device 3 Figure 43 In this topology, the configuration of each device is as follows; Device 1: Set the second bit of DIP-switches ON, and others OFF; use two E1, time slot 0 and single E1 direction.
  • Page 69: Alarm Sound Set

    Raisecom Technology Co., Ltd 0 and single E1 direction. Device 5: Set all DIP-switches OFF; use one E1, time slot 0 and single E1 direction. To avoid error the above configuration is recommended. 10.9.7. Alarm Sound Set In system menu press number key 7 to configure the alarm sound:...
  • Page 70: Dcd And Rts Of V35V24 Board With Alarm Set

    Raisecom Technology Co., Ltd User-Board2(V35 User Board) Set Command:1-8, Menu Display:M, Return:Q Command: Note: the command explanation is available in 8.12 V35 User Board Set menu. When the user-board type is 8 (Ethernet data user-board), the menu will be: 1.Sub-Board Slot Number 2.Channel Select...
  • Page 71: Alarm Mask Set

    Raisecom Technology Co., Ltd 10.10.1. Alarm Mask Set In optical line-board set menu press number key 1 to configure optical alarm mask: Optical Alarm Mask Set: Local Optical Loss:(Enable) In this statu use → key to disable or enable alarm mask; use ↓↑to change items (alarms);...
  • Page 72: Ether Net Port Work Set

    Raisecom Technology Co., Ltd 10.10.5. Ether Net Port Work Set In optical line-board set menu press number key 5 to configure Ethernet interface work status: Ether Net Work State Set: Auto Mode:Enable In this statu use → key to change configured value (enable or disable); use ↓↑to change configuration items;...
  • Page 73: E1 Set

    Raisecom Technology Co., Ltd Run this command (Y/N): Press Y key to confirm the operation and press N key to return, others keys are invalid. 10.11. E1 Set This section will explain the command in E1 Set menu. 10.11.1. Use Set...
  • Page 74: Crc Set

    Raisecom Technology Co., Ltd Fourth E1; Fourth E1 LOS; Fourth E1 AIS; Fourth E1 LOF Fourth E1 RAL; Fourth E1 LOMF; Fourth E1 CRC LOMF Fourth E1 CRC Alarm Note: if the line-board is 2E1 line-board only 2 E1 can be configured.
  • Page 75: Signal Bit

    Raisecom Technology Co., Ltd 10.12.3. Signal Bit In user board set menu press number key 3 to configure the signal bit: First Channel Signal Bit:A In this status use → key to change signal bit; use ↓↑to change configuration items; Press ENTER to confirm configuration, press E key to finish configuration, and ESC to cancel configuration.
  • Page 76: Receive Data Phase

    Raisecom Technology Co., Ltd collision alarms. And limitation for main cross group (user E1 1) is: when V35 user-board uses main cross group to transfer data the number of channels will not same for different slots. Channel number range for first slot is 0-31, 0 indicates that shutdown the transmission, and the startup channel is channel 1.
  • Page 77: Loopback Set

    Raisecom Technology Co., Ltd 10.13.5. Loopback Set In V35 user board set menu press number key 5 to configure loopback status of V35 user board: Local Loopback Set:No Loopback In this status use → key to change loopback status; use ↓↑to change configuration items;...
  • Page 78: Ethernet User-Board Set Menu

    Raisecom Technology Co., Ltd 180-degree shift. Disable this function and set the Rx data phase positive: the Rx data phase will be 0 degree; disable this function and set the Rx data phase negative: the Rx data phase will be 180 degree; enable this function and set the Rx data phase positive: the Rx data phase will be 90 degree.
  • Page 79: Default Port Mode

    Raisecom Technology Co., Ltd 10.14.4. Default Port Mode In Ethernet user board set menu press number key 4 to set the default port mode: Default Port Model:Half Duplex In this status use → key to change the configured value: Full duplex of Half duplex;...
  • Page 80: Cross Set

    Raisecom Technology Co., Ltd 10.16.1. Cross Set In cross set menu press number key 1 to configure the cross connect: Input Group Number (1-8): First input the cross group number: First Channel: There are two parts of configured data for each channel: a group number and a channel...
  • Page 81: Delete Group Cross

    Raisecom Technology Co., Ltd In this statu use → to change the configured value: Retain & Clear, press ENTER to confirm. In the configuration process press ESC to exist and the above configurations will be invalid. (There are seven steps of this configurarion: Group No. for Time Slot Out, Time Slot Start No.
  • Page 82: Operate Menu

    Raisecom Technology Co., Ltd Delete cross connect of cross group 1 1-5 channels and its correlation configuration: Group No. for Delete Cross:1 Time Slot Start No. for Delete Cross:1 Time Slot Number for Delete Cross:5 Delete Releation:Clear Then cross connect of cross group 1 1-5 channels and its correlation configuration will be deleted.
  • Page 83: Clear Cross Set

    Raisecom Technology Co., Ltd Note: system initialization will set all configurations in 0 status, and parts restore to factory default value. All cross set will be cleared. 10.17.4. Clear Cross Set In operate menu press number key 4 to clear cross set: Run this command,the device will format all cross data.
  • Page 84: Version

    Raisecom Technology Co., Ltd Can not save data to EEPROM. 10.18. Version In main menu press number key 7 to get version information: 1.Display Version information Version Information Command: 1-1, Menu Display: M, Return: Q Command: 10.18.1. Display Version information In version menu press number key 1 to show device version information: Hardware Version:REV A.00...
  • Page 85: Quit

    Raisecom Technology Co., Ltd Enter your password and press ENTER for next entering: Input New Password Again: Enter your password and press ENTER to confirm (there will be * prompt for each entered character). If it is same with the last entered password, the password configuration will be successful;...
  • Page 86 Raisecom Technology Co., Ltd @2005 Raisecom Technology Co., Ltd. All trademarks are the property of their respective owners. Technical information may be subject to change without prior notification.

This manual is also suitable for:

Rc3000

Table of Contents