DESCRIPTION

Device Appearance

The SDX 611 GPON SFU ONT, 1GE (611 GPON ONT) is an Optical Network Unit or Terminal that leverages GPON technology for delivering premium 1GE services.
The 611 GPON ONT is an indoor unit that supports up to 1 Gbps data rates.
This document supports the following versions of the 611 GPON ONT.

Decription P/N
SDX 611 GPON SFU ONT, 1GE with NA power adapter (included) 1287833F1
SDX 611 GPON SFU ONT, 1GE with UK power adapter (included) 1287833F2
SDX 611 GPON SFU ONT, 1GE with EU power adapter (included) 1287833F3
SDX 611 GPON SFU ONT, 1GE with AU power adapter (included) 1287833F4

FEATURES

FEATURES
The basic features of the 611 GPON ONT include the following:

  • Single GPON fiber interface with 1.244 Gigabits per second upstream and 2.488 Gigabits per second downstream
  • 1 GE (RJ-45) Customer Interface
  • Remote activation and deactivation
  • Remote firmware upgrades and downgrades
  • Remote OMCI management as per ITU-T G.988
Callout Description
1 LEDs
2 GPON fiber interface
3 1 GE, RJ-45 Customer LAN Connection
4 Power Connection for the Supplied AC to DC Power Converter (12 V)
5 On/Off button

Power

Power is provided by a 12 V DC Power Adapter that is included with the 611 GPON ONT. The power adapter operates from a power source of 100 to 240 V AC, 50 - 60 Hz. For the United States and Canada applications, an NRTL Listed Limited Power Source (LPS) is needed. For deployment in international applications, an LPS specifically approved for that country, as indicated by a CE Mark, is needed.

INSTALLATION

After unpacking the unit, inspect it for damage. If damage is noted, file a claim with the carrier and then contact ADTRAN.

Installation Guidelines

The following are guidelines for basic installation of the 611 GPON ONT.


Read all warnings and cautions before installing or servicing the 611 GPON ONT.

Installation Overview

To install the 611 GPON ONT, you will need to complete the following steps:

  1. Install the 611 GPON ONT
  2. Connect Ethernet
  3. Connect Fiber
  4. Connect Power

Required Tools:
Be sure to route and secure the fiber and cables in a manner that will prevent damage. Standard technician tools and those listed below are required for installing the 611 GPON ONT.

  • Optical power meter with wavelength filtering
  • Fiberscope or videoscope
  • #2 Phillips-head screw driver
  • Drill
  • Hammer

For fiber optics connections, the following is required:

  • ODC Fiber Cleaning Tool

Install the device

There are two options to install the 611 GPON ONT: Desk Top and Wall Mount. Options are described below.

information NOTE
Included with the 611 GPON ONT is a 5-foot (1.5 m) power cord. All installation locations should be within 5 feet (1.5 m) of a wall outlet.

Desk Top Installation
The 611 GPON ONT can be located on a desktop.


Ensure that the 611 GPON ONT is not located in direct sunlight or next to any thermal obstructions.


Ensure that the 611 GPON ONT does not come in contact with water or other liquids.

Wall Mounting
Refer to figure below when installing the 611 GPON ONT on a wall.

  1. Decide on a location for the 611 GPON ONT. Mount below eye-level so the LEDs are visible.
    Wall Mounting

information NOTE
Supplied hardware is intended for drywall mounting only. For mounting on surfaces other than drywall, obtain the appropriate mounting hardware and follow the provided instructions.

  1. Use the keyholes on the rear of the 611 GPON ONT as a template and mark the wall accordingly. The keyhole spacing for a vertical mount is 1.97 inches (5 cm).
  2. Drill holes using a 1/4" drill bit into the marks on the wall.
  3. Use a hammer to lightly tap the included wall anchors into the drilled holes until anchor is flush with the wall.
  4. Install two included screws into the anchor heads. Leave approximately 1/4 inch (6 mm) protruding from the mounting surface.
  5. Slide the 611 GPON ONT over the screws and exert a small amount of downward pressure to ensure that the top of the slots are resting on the shafts of the screws.

Connect Ethernet

Refer to Figure 2 and insert a Category 5E (or better) RJ-45 cable into the port labeled GE until there is an audible "click".

Connect Fiber


To prevent breaking the fiber, do not exceed the fiber bend radius of 3.5 in. (8.9 cm).


LASER RADIATION - 1310 nm to 1600 nm

Do not view directly with optical instruments.

Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

Fiber is installed in an SC/APC connector (OPTICAL) located on the rear of the 611 GPON ONT (see Figure 2). Complete the following steps to install fiber.

  1. Remove the Dust Cover from the SC/APC Connector.
  2. Clean the end of the Incoming Fiber Connector.
  3. Before installing the fiber, use an optical power meter to measure the dB power. The level should not exceed –8 dB. Use an appropriate bi-directional optical attenuator if the power levels are at or above –8 dB. A level between –12 and –27 dBm is acceptable.
  4. Connect the Incoming Fiber Connector.

Connect Power

To connect power to the 611 GPON ONT, complete the following steps:

  1. Plug the supplied 12 V AC/DC Power Adapter into the 12V connection on the rear of the 611 GPON ONT.
  2. Connect the Power Adapter to a standard 100 - 240 V AC outlet.
  3. Press the POWER button to turn the 611 GPON ONT on.
  4. Verify power is on by checking the power LED on the 611 GPON ONT. The LED should be green, indicating local power is on.

information NOTE
ADTRAN recommends only using the DC power adapter that is provided with the unit.


For United States and Canada applications, the DC Power Adapter must be an NRTL Listed LPS power supply. For International applications, the DC Power Adapter must be an LPS power supply specifically approved for that country.

LEDs

When the 611 GPON ONT first powers up it performs self-tests. Once the power up self-tests are complete, the status LEDs will reflect the state of the hardware. The table below details the status indicated by the LEDs.

LED Status Indication
Power
Off Power is off
Green Power is on, self-test passed, normal operation
Green Flashing Unit is powering up
Optical
Green ONU ranged, authenticated, and configured with services
Green Flashing (Fast) ONU is ranging and synchronization process in progress
Green Flashing (Slow) ONU ranged and authenticated but not configured with services
Red PON is down due to LOF/LOS
LAN
Off No Ethernet connectivity
Green Ethernet connectivity present, no activity
Green Flashing Ethernet connectivity present, activity detected Interface operation state is up and packets Tx/Rx detected on the interface
Alarm/
Update
Off No alarm detected
Green ONU software download complete and software upgrade in progress. ONU LED will turn off once upgrade is successful
Green Flashing ONU software download in progress
Red ONU is powered up and PON operational state is up and ONU software upgrade failed. New ONU software not operational due to any of the following reasons:
  • Software image download failed
  • Software image flash write failed
  • Software image activation failed
  • Software image commit failed

SPECIFICATIONS

Specifications for the 611 GPON ONT are as follows:

  • Electrical
    • Input: 12 V DC, 0.5 A
    • Maximum Power Consumption: 6 W
    • Power Supply Adapter: 12 V DC Power Adapter
      • Input Voltage Rating: 100 - 240 V AC, 50/60 Hz
      • Output Voltage Rating: 12 V DC
      • Output Current Rating: 0.5 A (minimum)
  • Physical
    • Height: 0.95 in (2.40 cm)
    • Width: 3.15 in (8.00 cm)
    • Depth: 3.15 in (8.00 cm)
    • Weight: 0.20 lbs (0.09 kg)
  • Environmental
    • Operational Temperature Range: 0°C to +40°C
    • Storage Temperature Range: –40°C to +70°C
    • Relative Humidity: up to 95%, noncondensing
  • Optical
    • TX min power: +0.5 dBm
    • TX max power: +5.0 dBm
    • RSSI max sensitivity: –27.0 dBm
    • RX overload: –8.0 dBm
    • TX wavelength: 1310 nm typical
    • RX wavelength: 1490 nm typical

MAINTENANCE

The 611 GPON ONT does not require routine hardware maintenance for normal operation. ADTRAN does not recommend that repairs be attempted in the field. Repair services may be obtained by returning the defective unit to ADTRAN. Field support for software is provided through upgrade facilities.

SAFETY AND REGULATORY

Refer to the Safety and Regulatory Notice for this product (P/N: 61287833F1-17) for detailed safety and regulatory information.
Registration is required.
ADTRAN offers training courses on our products, including customized training and courses taught at our facilities or at customer sites.
For inquiries, go to: https://www.adtran.com/index.php/training


SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY HANDLING PRECAUTIONS REQUIRED

ADTRAN CUSTOMER CARE:
From within the U.S. 1.888.423.8726
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807

Trademarks:
Brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective holders.
Copyright © 2020 ADTRAN, Inc. All Rights Reserved.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download ADTRAN SDX 611 GPON SFU ONT - Optical Network Unit with GPON for 1GE Quick Start Manual

Advertisement

Need Assistance?

Do you have a question about the SDX 611 GPON SFU ONT that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents