take effect. You can directly adjust the set main frequency by pressing keys
on the operation panel (or using the UP/DOWN function of input terminals).
If the auxiliary frequency source is analog input (AI1, AI2 and Keyboard potentiometer) or
pulse setting, 100% of the input corresponds to the range of the auxiliary frequency Y (set
in P0-05 and P0-06).
If the auxiliary frequency source is pulse setting, it is similar to analog input.
The main frequency source X and auxiliary frequency source Y must not use the same
channel. That is, P0-03 and P0-04 cannot be set to the same value.
Function
Code
Range of auxiliary frequency Y
P0-05
Range of auxiliary frequency Y
P0-06
If X and Y operation is used, P0-05 and P0-06 are used to set the adjustment range of the
auxiliary frequency source.
You can set the auxiliary frequency to be relative to either maximum frequency or main
frequency X. If relative to main frequency X, the setting range of the auxiliary frequency Y varies
according to the main frequency X.
Function
Parameter Name
Code
Frequency source
P0-07
Parameter Name
for X and Y operation
for X and Y operation
selection
Note
Setting Range
0: Relative to maximum frequency
1: Relative to main frequency X
Setting Range
Unit's digit (Frequency source selection)
0: Main frequency source X
1: X and Y operation
(operation relationship determined by ten's
digit)
2: Switchover between X and Y
3: Switchover between X and "X and Y
operation"
4: Switchover between Y and "X and Y
operation"
81
Description of Function Codes
0%–150%
and
Default
0
0
Default
0