Figure 5-15 Forward/Reverse rotation dead-zone time
P8-13
Setting Range
It is used to set whether the AC drive allows reverse rotation. In the applications where reverse
rotation is prohibited, set this parameter to P8-13=1.
Running mode when set
frequency lower than
frequency lower limit
P8-14
Setting Range
It is used to set the AC drive running mode when the set frequency is lower than the frequency
lower limit. The PE6000 provides three running modes to satisfy requirements of various
applications.
P8-15
This function is used for balancing the workload allocation when multiple motors are used to
drive the same load.
The output frequency of the AC drives decreases as the load increases. You can reduce the
workload of the motor under load by decreasing the output frequency for this motor, implementing
workload balancing between multiple motors.
The parameter indicates the drop-out value of output frequency when AC driver outputs rated
load.
Accumulative power-on time
P8-16
If the accumulative power-on time (P7-13) reaches the value set in P8-16, the corresponding
DO terminal becomes ON.
Reverse control
0
1
0
1
2
Droop control
Setting Range
threshold
Setting Range
Default
Enabled
Disabled
Default
Run at frequency lower limit
Stop
Run at zero speed
Default
0.00–10.00 Hz
Default
0–65000 h
131
Description of Function Codes
0
0
0.00Hz
0h