Function Code Tables
Function
Parameter
Code
Name
DI1
P4-00
function
selection
DI2
P4-01
function
selection
DI3
P4-02
function
selection
DI4
P4-03
function
selection
DI5
P4-04
function
selection
Setting Range
Group F4: Input Terminals
0:No function
1:Forward RUN (FWD)
2:Reverse RUN (REV)
3:Three-line control
4:Forward JOG (FJOG)
5:Reverse JOG (RJOG)
6:Terminal UP
7:Terminal DOWN
8:Coast to stop
9:Fault reset (RESET)
10:RUN pause
11:Normally open (NO) input of external fault
12:Multi-reference terminal 1
13:Multi-reference terminal 2
14:Multi-reference terminal 3
15:Multi-reference terminal 4
16:Terminal 1 for acceleration/ deceleration time selection
17:Terminal 2 for acceleration/ deceleration time selection
18:Frequency source switchover
19:UP and DOWN setting clear (terminal, operation panel)
20:Command source switchover terminal 1
21:Acceleration/Deceleration prohibited
22:PID pause
23:PLC status reset
24:Swing pause
25:Counter input
26:Counter reset
27:Length count input
28:Length reset
29:Torque control prohibited
30:Pulse input (enabled only for DI5)
31:Reserved
32:Immediate DC braking
33:Normally closed (NC) input of external fault
34:Frequency modification
Forbidden
35:Reverse PID action direction
36:External STOP terminal 1
37:Command source switchover terminal 2
38:PID integral pause
39:Switchover between main frequency source X and preset
frequency
40:Switchover between auxiliary frequency source Y and
preset frequency
41:Motor selection terminal 1
42:Motor selection terminal 2
43:PID parameter switchover
44:User-defined fault 1
45:User-defined fault 2
46:Speed control/Torque control switchover
47:Emergency stop
48:External STOP terminal 2
49:Deceleration DC braking
50:Clear the current running time
51–59: Reserved
52
PE6000 User Manual
Default Property
1
2
4
9
12