Pioneer PE6000 Series User Manual page 102

Table of Contents

Advertisement

Description of Function Codes
Value
Terminal 1 for
16
acceleration/ deceleration
time selection
Terminal 2 for
17
acceleration/ deceleration
time selection
Frequency source
18
switchover
UP and DOWN setting
19
clear (terminal, operation
Command source
20
switchover terminal
Acceleration/Deceleration
21
22
PID pause
23
PLC status reset
24
Swing pause
25
Counter input
26
Counter reset
29
Torque control prohibited
Pulse input (enabled only
30
31
32
Immediate DC braking
Normally closed (NC)
33
input of external fault
Function
panel)
prohibited
for DI5)
Reserved
Totally four groups of acceleration/deceleration time
can be selected through combinations of four states of
these two terminals. For details please refer to the
Appendix table 2.
The terminal is used to perform switchover between two
frequency sources according to the setting in P0-07.
If the frequency source is digital setting, the terminal is
used to clear the modification by using the UP/
DOWN function or the increment/decrement key on the
operation panel, returning the set frequency to the
value of P0-08.
If the command source is set to terminal control (P0-02
= 1), this terminal is used to perform switchover
between terminal control and operation panel control.
If the command source is set to communication control
(P0-02 = 2), this terminal is used to perform switchover
between communication control and operation panel
control.
It enables the AC drive to maintain the current
frequency output without being affected by external
signals (except the STOP command).
PID is invalid temporarily. The AC drive maintains the
current frequency output without supporting PID
adjustment of frequency source.
The terminal is used to restore the original status of
PLC control for the AC drive when PLC control is
started again after a pause.
The AC drive outputs the central frequency, and the
swing frequency function pauses.
This terminal is used to count pulses.
This terminal is used to clear the counter status.
The AC drive is prohibited from torque control and
enters the speed control mode.
DI5 is used for pulse input.
Reserved.
After this terminal becomes ON, the AC drive directly
switches over to the DC braking state.
After this terminal becomes ON, the AC drive reports
Err15 and stops.
102
PE6000 User Manual