Appendix B
Function code group number
Group P0-PE
Group A0-AC
Group U0
Attention: if being used frequently, the lifespan of EEPROM will be shortened. So, some function
codes cannot be stored under the model of communication, and you only need to change the value
of RAM.
For parameters in group P, you only need to change F to 0 in high byte of function code address to
implement this function.
For parameters in group A, you only need to change A to 4 in high byte of function code address to
implement this function.
Relevant function code address is as follows:
High byte: 00-0F(group F)、40-4F(group A)
Low byte: 00-FF
For example:
Function code P3-12 is not stored in EEPROM, 030C indicates the address.
Function code A0-05 is not stored in EEPROM, 4005 indicates the address.
These addresses indicate that RAM can only be written, but cannot be read. The addresses are
invalid while reading.
For all parameters, the function can be implemented by command code 07H.
Stop/Operation parameters:
Parameter
address
1000H
1001H
1002H
1003H
1004H
1005H
communication access
Parameter description
Communication setting
value(decimal)
Running frequency
Bus voltage
Output voltage
Output current
Output power
address
0xF000-0xFEFF
0xA000-0xACFF
0x7000-0x70FF
Parameter
address
1010H
1011H
1012H
1013H
1014H
1015H
202
PE6000 User Manual
Function code address while
modifying RAM
0x0000-0x0EFF
0x4000-0x4CFF
Parameter description
PID setting
PID feedback
PLC procedure
input pulse frequency, unit
0.01kHz
Feedback speed, unit 0.1Hz
Remaining running time