Pioneer PE6000 Series User Manual page 71

Table of Contents

Advertisement

PE6000 User Manual
Function
Parameter Name
Code
PD-00
PD-01
Data format
PD-02
Local address
PD-03
Response delay
PD-04
Communication timeout
Modbus protocol
selection and
PD-5
PROFIBUS-DP data
Communication reading
PD-06
current resolution
Master and slave
PD-07
Function
Parameter Name
Code
PP-00
User password
PP-01
Restore default settings
Group PD: Communication Parameters
Unit's digit (Modbus baud rate)
0: 300 BPs
1: 600 BPs
2: 1200 BPs
Baud rate
3: 2400 BPs
4: 4800 BPs
5: 9600 BPs
6: 19200 BPs
7: 38400 BPs
8: 57600 BPs
9: 115200 BPs
0: No check, data format <8,N,2>
1: Even parity check, data format
<8,E,1>
2: Odd Parity check, data format
<8,O,1>
3: No check, data format <8,N,1>
Valid for Modbus
1–247
0–20 ms
0.0s (invalid) 0.1–60.0s
Unit's digit: Modbus protocol
0: Non-standard Modbus protocol
1: Standard Modbus protocol
format
0: 0.01A
1: 0.1A
0: master
selection
1: slave
Group PP: Function Code Management
0–65535
0: No operation
01: Restore factory settings except
motor parameters
02: Clear records
04: Restore user backup parameters
501: Back up current user
parameters
Setting Range
Setting Range
71
Function Code Tables
Propert
Default
y
5
0
1
2 ms
0.0s
0
0
0
Default Property
0
0

Hide quick links:

Advertisement

Table of Contents
loading