Description of Function Codes
receiving the stop command.
Function
Parameter Name
Code
Simple PLC retentive
PC-17
PLC retentive upon power failure indicates that the AC drive memorizes the PLC running
moment and running frequency before power failure and will continue to run from the memorized
moment after it is powered on again. If the unit's digit is set to 0, the AC drive restarts the PLC
process after it is powered on again.
PLC retentive upon stop indicates that the AC drive records the PLC running moment and
running frequency upon stop and will continue to run from the recorded moment after it starts up
again. If the ten's digit is set to 0, the AC drive restarts the PLC process after it starts up again.
Function
Code
PC-18
Running time of simple PLC reference 0
Acceleration/deceleration time of simple PLC
PC-19
PC-20
Running time of simple PLC reference 1
Acceleration/deceleration time of simple PLC
PC-21
PC-22
Running time of simple PLC reference 2
Acceleration/deceleration time of simple PLC
PC-23
PC-24
Running time of simple PLC reference 3
Acceleration/deceleration time of simple PLC
PC-25
PC-26
Running time of simple PLC reference 4
Acceleration/deceleration time of simple PLC
PC-27
PC-28
Running time of simple PLC reference 5
Unit's digit (Retentive upon power failure)
0: No
1: Yes
selection
Ten's digit (Retentive upon stop)
0: No
1: Yes
Parameter Name
reference 0
reference 1
reference 2
reference 3
reference 4
Setting Range
162
PE6000 User Manual
Setting Range
0.0–6553.5s (h)
0–3
0.0–6553.5s (h)
0–3
0.0–6553.5s (h)
0–3
0.0–6553.5s (h)
0–3
0.0–6553.5s (h)
0–3
0.0–6553.5s (h)
Default
00
Default
0.0s (h)
0
0.0s (h)
0
0.0s (h)
0
0.0s (h)
0
0.0s (h)
0
0.0s (h)