PE6000 User Manual
Function
Parameter
Code
Name
P7-03
P7-04
These two parameters are used to set the parameters that can be viewed when the AC drive is
in the running state. You can view a maximum of 32 running state parameters that are displayed
from the lowest bit of p7-03.
0000-FFFF
7
6
5
4
3
15
14
13
12
If a parameter needs to be displayed during the running,
set the corresponding bit to 1, and set 7-03 to the
hexadecimal equivalent of this binary number.
0000-FFFF
7
6
5
4
3
15
14
13
12
If a parameter needs to be displayed during the running,
set the corresponding bit to 1, and set 7-04 to the
hexadecimal equivalent of this binary number.
Setting Range
2
1
0
Running frequency1 (Hz)
Set frequency (Hz)
Bus voltage (V)
Output voltage (V)
Output current (A)
Output power (kW)
Output torque (%)
DI input status
11
10
9
8
2
1
0
PID feedback
PLC stage
Pulse setting frequency (kHz)
Running frequency 2
Remaining running time
AI1 voltage before correction
AI2 voltage before correction
AI3 voltage before correction
11
10
9
8
Linear speed
Current power-on time (Hour)
Current running time (Minute)
Pulse setting frequency (Hz)
Communication setting value
Encoder feedback speed (Hz)
Main frequency X display (Hz)
Auxiliary frequency Y display (Hz)
125
Description of Function Codes
DO output status
AI1 voltage (V)
AI2 voltage (V)
AI3 voltage (V)
Count value
Length value
Load speed display
PID setting
Default
001F
0000