Operation Oem6 Cards And Enclosure; Communications With The Receiver; Basic Oem6 Family Card Connection Interfaces (Example) - Novatel OEM6 Series User Manual

Hide thumbs Also See for OEM6 Series:
Table of Contents

Advertisement

Chapter 4
Before operating the receiver for the first time, read the installation instructions in Chapter 2, Installation
OEM6 Family Cards on page 22 or Chapter 3, Installation FlexPak6 on page 36. The following
instructions are based on a configuration similar to Figure 17.
Figure 17: Basic OEM6 Family Card Connection Interfaces (example)
GNSS
Antenna
RF cable
Data Logger
or Rover
External DC Power
Data
Network
Ethernet Link (OEM628,
OEM638 or FlexPak6)
Note the figure above does not show all necessary hardware. Also see Figure 18, Basic
Differential Setup on Page 47 for a base/rover example.
COM3 is LVTTL and signal conversion may be required depending on the equipment
connected.
4.1

Communications with the Receiver

Communication is established with the receiver using a data terminal or computer connected to one of
the receiver's serial ports using a null modem, USB or Ethernet cable.
When connected to the receiver, enter commands directly from the terminal or through terminal
emulation software (such as NovAtel Connect or HyperTerminal) on a computer.
To maximize the application of the receiver's capabilities, become familiar with the commands and logs
described in the
OEM6 Family Firmware Reference Manual
42

Operation OEM6 Cards and Enclosure

NovAtel Receiver Card
COM2
Power Input
User supplied Enclosure
COM1
COM3
External Oscillator
Signal (OEM628 or
OEM638)
or
FlexPak6
(OM-20000129).
OEM6 Family Installation and Operation User Manual Rev 7
Computer or
Base Station
Computer with
NovAtel USB
drivers installed
USB
External
Oscillator

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oem615Oem617dOem628Oem638

Table of Contents