Oem638 And Oem638V Keep-Out Zone - Novatel OEM6 Series User Manual

Hide thumbs Also See for OEM6 Series:
Table of Contents

Advertisement

0.00
2.85
3.69
21.58
75.05
Notes:
1. Dimensions are in millimeters [inches].
2. Keep-out areas are intended for NovAtel circuitry.
Operating Temperature
Storage Temperature
Humidity
Random Vibration
Random Vibration
(OEM638V only)
Sinusoidal Vibration
Bump
Shock
Acceleration
OEM6 Family Installation and Operation User Manual Rev 7
Figure 76: OEM638 and OEM638V Keep-Out Zone
125.0
Processor Side
ENVIRONMENTAL
-40C to +85C
-40C to +95C
MIL-STD-810G, Method 507.5, Procedure II (95%)
MIL-STD 810G, Category 24 (20 Hz to 2000 Hz, 7.7 g RMS) and
MIL-STD-810G, Method 514.6, Category 4 (5 Hz to 500 Hz, 2.3 g RMS)
MIL-STD 810G, Category 24 (20 Hz to 20000 Hz, 20 g RMS) and
MIL-STD-810G, Method 514.6, Category 4 (5 Hz to 500 Hz, 2.3 g RMS)
IEC 60068-2-6 (10 Hz to 2 kHz, 5 g)
ISO 9022-31-06 (25 g)
Operating - MIL-STD-810G, Method 516.6, Procedure I (40 g)
Non-operating - MIL-STD-810G, Method 516.6, Procedure V (75 g)
MIL-STD-810G, Method 510.6, Procedure II (4 g, 8 g, 12 g, 16 g)
TCXO Shield Keepout
85.0
Processor Side Keepout
147