Examining the AUX1 Status Word

Table 12 provides actions to take when your receiver has an error flag in the AUX1 status word .
Bit Set
0-2
(Reserved bits)
3
None. This bit indicates that Position Averaging is ON
4-6
(Reserved bits)
7
Connect the receiver via USB
8-10
Reduce the amount of logging on the USB ports
11-13
(Reserved bits)
AGC error on RF1 through RF4 respectively. To resolve, ensure the antenna cable is
14-17
connected and signal input level is within specification
18
Connect the receiver via Ethernet. See Section 4.7.7 Ethernet on page 65
19-21
Reduce the amount of logging on the Ethernet ports
22-24
Reduce the amount of logging on the NTRIP ports
25-27
Reduce the amount of logging on the Virtual COM ports
28-31
(Reserved bits)
88
Table 12: Resolving an Error in the AUX1 Status Word