The FlexPak6 provides an output voltage on pin 4 of COM2 (POUT) that matches the
voltage used to power the FlexPak6.
The FlexPak6 can accept voltages up to 36 VDC, which is greater than the RS-232 specified
maximum 25 VDC. As a result, you can damage equipment that is connected to COM2 by
sending voltages higher than the RS-232 specification allows.
Connector
Signal Name
Pin No.
1
ETH_TD+
2
ETH_RD+
3
CAN1+
4
No connect
5
GND
6
ETH_TD-
7
ETH_RD-
8
CAN1-
9
MODE
10
EVENT2
11
EVENT1
12
VARF
13
ERROR
14
PV
15
PPS
Also see "Strobes" on Page 63.
OEM6 Family Installation and Operation User Manual Rev 7
Table 31: FlexPak6 I/O Port Pin-Out Descriptions
Input/Output
Input/Output
Input/Output
Input/Output
Digital ground
Input/Output
Input/Output
Input/Output
Input
When grounded (e.g., connected to pin 5), enables
RS-422 mode for COM2. RS-232 is the
unconnected default
Input
Mark 2 input. This input has in internal pull-down
and buffers the input to the OEM628 card
Input
Mark 1 input. This input has in internal pull-down
and buffers the input to the OEM628 card
Output
Variable frequency out
Output
Indicates a fatal error when high. The antenna port
LED also turns red during a fatal error
Output
Valid position available. The antenna port LED also
turns green for a valid position
Output
Pulse per second