Comtrol InterChange VS 3000 Series Installation And Configuration Manual page 64

Table of Contents

Advertisement

Error Codes and System Messages
Code
CAPI3000 E004:
CAPI3000 E005:
CAPI3000 E006:
CAPI3000 E007:
CAPI3000 E008:
CAPI3000 E009:
CAPI3000 E010:
64
Table 6. CAPI3000 Error Codes
Message and Description
Error, cannot register more than n applications, rejected!
Since buffer pools and other resources are dedicated to
each particular application, more than a certain number
would have adverse impact on performance. This console
message indicates that an application has attempted to
register with the VS3000 stack after all available
application slots were registered.
Note: PPP is considered one application
Error allocating application control structure!
Application registration failed due to lack of available
memory. Error returned to CAPI, registration failed.
Error, illegal Application ID nn!
Release by unrecognized application failed, application
identifier is too large, should be from the set {0-3}. Error
returned to CAPI, registration failed.
Error, application not found for ID nn!
Release by unrecognized application failed, application
identifier was not in use. Error returned to CAPI,
registration failed.
Error, stale Application ID nn!
Release by unrecognized application failed, application
identifier supplied by application didn't match one
retained by VS3000 ISDN driver. Error returned to CAPI,
registration failed.
Error, invalid CAPI subcommand <0xhh>!
The CAPI subcommand (properly either a request or
response) was unrecognized and the command was
discarded with an error response to CAPI. Valid
subcommands are {80, 81, 82, 83}.
Insufficient memory available for virtual server
information!
Couldn't allocate sufficient space for interface
configuration data. Fatal, since driver initialization fails.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Interchange vs3000uInterchange vs3000s