Ametek 5800 User Manual page 65

Moisture
Table of Contents

Advertisement

Variables Table
Name
ID
Press Units
13
MaxZeroError
18
MaxZeroDrift
19
AnalogOutSpan
29
AnalogOutOffset
30
Baud
40
SerialMode
41
NodeAddress
42
AnalyzerName
43
Gas
44
Alarm1Hi
46
Alarm1Lo
47
MaxCalError
55
KFactor
56
CalHour
57
CalPeriod
58
CalMonthDays
59
CalWeekDays
60
CalType
61
SerialNumber
62
CellSerialNumber
63
MoistureGeneratorSN
64
Version
65
HoldOut
69
VerDurationLimit
71
ZeroOnly
72
EnableAlarm1
73
DryerDateCode
75
DryerPpmHours
76
LCDcontrast
79
LCDbacklight
80
AdjustFreqOffset
81
ZeroHour
82
ZeroPeriod
83
ZeroMonthDays
84
ZeroWeekDays
85
ZeroType
86
Pressure1
87
CellTemp
88
AnalogOutput
89
EETemp
90
Moisture
91
HeldConc
92
Frequency
93
DeltaFrequency
94
Flow3
97
ValveState
99
Hour
100
HEX
Description
D
Process pressure units of measure
12
Maximum zero error allowed
13
Maximum zero drift allowed
1D
Analog output span
1E
Analog output offset
28
Serial communication speed
29
RS-485 two wire or four wire mode
2A
RS-485 analyzer address
2B
Ametek analyzer name
2C
Sample gas name
2E
High concentration limit
2F
Low concentration limit
37
Maximum verifi cation error allowed
38
Gas based coeffi cient
39
Verifi cation schedule parameter
3A
Verifi cation schedule parameter
3B
Verifi cation schedule parameter
3C
Verifi cation schedule parameter
3D
Verifi cation schedule parameter
3E
Analyzer manufacturing number
3F
Sensor manufacturing code
40
Moisture generator production code
41
Embedded software version
45
Hold out during zero and verifi cation
47
Minimum verifi cation cycles number
48
Start zero only fl ag
49
Enable or disable concentration alarm
4B
Dryer production code
4C
Dryer consumption in 1000 ppm hours
4F
Display contrast setting
50
Display back light on or off
51
Adjust frequency offset after zero
52
Zero schedule parameter
53
Number of cycles to stay in zero
54
Zero schedule parameter
55
Zero schedule parameter
56
Zero type(daily,monthly,weekly)
57
Sensor pressure value
58
Sensor temperature value
59
Current output reading
5A
Electronics enclose temperature
5B
Moisture concentration reading
5C
Held moisture concentration reading
5D
Sensor frequency reading
5E
Wet minus dry reading
61
Held and displayed fl ow
63
0-sample, 1-ver, 2-reference, 3-zero
64
Analyzer current time read
Type
Typical Value
Integer
0
Float
0.5
Float
1.0
Float
1.0
Float
0.0
Integer
9600
Integer
1(four wire)
String
1
String
5830
String
Nitrogen
Float
100.0
Float
0.0
Float
unused
Float
1.0
Integer
13
Integer
15
Integer
1
Integer
1
Integer
0
String
123
String
583015
String
020101305012
String
1.00
Integer
1(hold)
Integer
15
Integer
1(zero only)
Integer
1(enable)
String
010080009
Float
20000.00
Integer
5
Integer
1(on)
Integer
1(adjust)
Integer
13
Integer
15
Integer
1
Integer
1
Integer
0(daily)
Float
14.7 psi
Float
60.0 degreeC
Float
12.0 mA
Float
55.0 degreeC
Float
20.0 ppm
Float
22.0 ppm
Float
1200 Hz
Float
0.01 Hz
Float
50.0 sccm
Integer
0 (sample)
Integer
13
Serial Communications
|
5-7