Operation Via Ams Device Manager (Hart); Features And Functions; Startup And Configuration; Electronic Device Description (Edd) - Siemens SITRANS LUT400 Operating Instructions Manual

Ultrasonic controllers
Hide thumbs Also See for SITRANS LUT400:
Table of Contents

Advertisement

8.3

Operation via AMS Device Manager (HART)

8.3.1

Features and Functions

SITRANS LUT400 compatible with AMS version 10.5 and higher
AMS Device Manager is a software package used to commission and maintain SITRANS
LUT400 and other process devices. AMS Device Manager monitors the process values,
alarms and status signals of the device. It allows you to display, compare, adjust, verify, and
simulate process device data. The graphic interface in SITRANS LUT400 makes monitoring
and adjustments easy. Please consult the operating instructions or online help for details on
using AMS Device Manager. (You can find more information at:
http://www.emersonprocess.com/AMS/ (http://www.emersonprocess.com/AMS/).)
AMS Device Manager features four Quick Start Wizards (Level, Volume, Volume-
Linearization, and Flow) to easily configure the SITRANS LUT400. A Pump Control Wizard is
also available. Other features include Echo Profile viewing, TVT setup, Process Variables
monitoring, and Security.
Parameters organized into three main function groups allow you to configure and monitor the
device:
● Configure/Setup
● Device Diagnostics (read only)
● Process Variables (read only)
For a chart
The menu structure for AMS Device Manager is almost identical to that of the LCD.
1)
Communications for SITRANS LUT400 (HART) Manual (7ML19985NE01).
2)
8.3.2

Startup and Configuration

To startup the SITRANS LUT400 using AMS Device Manager, you must first install the EDD
(see below). You can then configure the device using the Quick Start Wizards in AMS.
For more information on AMS functions, and details on how to configure the device using
AMS, refer to the LUT400 Communications manual
Communications for SITRANS LUT400 (HART) Manual (7ML19985NE01).
2)
8.3.2.1

Electronic Device Description (EDD)

SITRANS LUT400 requires the EDD for AMS Device Manager version 10.5.
You can locate the EDD in Device Catalog, under Sensors/Level/Echo/Siemens/SITRANS
LUT400. Check the product page of our website at www.siemens.com/sitransLUT400
(www.siemens.com/sitransLUT400), under Support > Software Downloads, to make sure
you have the latest version of the EDD for AMS Device Manager.
164
AMS Menu Structure
of the
1
, see LUT400 Communications manual
.
2
Operating Instructions, 07/2019, A5E33329501-AC
2.
SITRANS LUT400