Document Conventions; Iec 61850 Edition 1 / Edition 2 Mapping - ABB Relion 670 Series Applications Manual

Phasor measurement unit
Hide thumbs Also See for Relion 670 Series:
Table of Contents

Advertisement

1MRK 511 407-UUS Rev. J
Although warning hazards are related to personal injury, it is necessary to understand that under
certain operational conditions, operation of damaged equipment may result in degraded process
performance leading to personal injury or death. It is important that the user fully complies with all
warning and cautionary notices.
1.4.2

Document conventions

Abbreviations and acronyms in this manual are spelled out in the glossary. The glossary also
contains definitions of important terms.
Push button navigation in the LHMI menu structure is presented by using the push button
icons.
For example, to navigate between the options, use
HMI menu paths are presented in bold.
For example, select Main menu/Settings.
LHMI messages are shown in Courier font.
For example, to save the changes in non-volatile memory, select Yes and press
Parameter names are shown in italics.
For example, the function can be enabled and disabled with the
Each function block symbol shows the available input/output signal.
Dimensions are provided both in inches and millimeters. If it is not specifically mentioned
then the dimension is in millimeters.
1.5

IEC 61850 edition 1 / edition 2 mapping

Function block names are used in ACT and PST to identify functions. Respective function block
names of Edition 1 logical nodes and Edition 2 logical nodes are shown in the table below.
Table 1:
Function block name
AEGPVOC
AGSAL
ALMCALH
ALTIM
ALTMS
Table continues on next page
Phasor measurement unit RES670
Application manual
The information icon alerts the reader of important facts and conditions.
The tip icon indicates advice on, for example, how to design your project or how to
use a certain function.
the character ^ in front of an input/output signal name indicates that the signal name
may be customized using the PCM600 software.
the character * after an input signal name indicates that the signal must be connected
to another function block in the application configuration to achieve a valid application
configuration.
IEC 61850 edition 1 / edition 2 mapping
© Copyright 2017 Hitachi Power Grids. All rights reserved
Edition 1 logical nodes
AEGGAPC
AGSAL
SECLLN0
ALMCALH
-
-
GUID-96DFAB1A-98FE-4B26-8E90-F7CEB14B1AB6 v9
and
.
Operation setting.
GUID-C5133366-7260-4C47-A975-7DBAB3A33A96 v8
Edition 2 logical nodes
AEGPVOC
AGSAL
ALMCALH
ALTIM
ALTMS
Section 1
Introduction
.
19