ABB Relion 670 Series Communication Protocol Manual
Hide thumbs Also See for Relion 670 Series:

Advertisement

Quick Links

®
Relion
670 SERIES
LON, 670 series
Version 2.2
Communication protocol manual

Advertisement

Table of Contents
loading

Summary of Contents for ABB Relion 670 Series

  • Page 1 ® Relion 670 SERIES LON, 670 series Version 2.2 Communication protocol manual...
  • Page 3 Document ID: 1MRK 511 395-UEN Issued: May 2019 Revision: E Product version: 2.2 © Copyright 2017 ABB. All rights reserved...
  • Page 4 Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software and hardware described in this document is furnished under a license and may be used or disclosed only in accordance with the terms of such license.
  • Page 5 This document has been carefully checked by ABB but deviations cannot be completely ruled out. In case any errors are detected, the reader is kindly requested to notify the manufacturer.
  • Page 6 (Low-voltage directive 2006/95/EC). This conformity is the result of tests conducted by ABB in accordance with the product standard EN 60255-26 for the EMC directive, and with the product standards EN 60255-1 and EN 60255-27 for the low voltage directive. The...
  • Page 7: Table Of Contents

    Communication via the rear ports ..................33 6.1.1.1 LON communication........................ 33 6.1.2 Settings............................33 6.1.2.1 Optical budget calculation for serial communication with LON ........34 6.1.2.2 Reference........................... 34 LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 8 Function block..........................40 7.2.4 Signals............................41 7.2.5 Settings............................42 7.2.6 Operation principle........................42 Synchronization alternatives......................43 7.3.1 Synchronization via serial communication module (SLM)..........43 Settings..............................43 Section 8 Glossary......................45 Glossary............................. 45 LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 9: Introduction

    Operation manual Application manual Technical manual Communication protocol manual Cyber security deployment guideline IEC07000220-4-en.vsd IEC07000220 V4 EN-US Figure 1: The intended use of manuals throughout the product lifecycle LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 10: Document Revision History

    Functions CHMMHAI, VHMMHAI, DELVSPVC, DELISPVC and DELSPVC added. Updates/ enhancements made to ZMFPDIS, ZMFCPDIS, CCRBRF, REALCOMP, PTRSTHR and FNKEYMDx. Ordering section updated. 2019-05 2.2.3 PTP enhancements and corrections LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 11: Related Documents

    Document numbers Application manual 1MRK 506 369-UEN Commissioning manual 1MRK 506 371-UEN Product guide 1MRK 506 372-BEN Technical manual 1MRK 506 370-UEN Type test certificate 1MRK 506 372-TEN LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 12: Document Symbols And Conventions

    It might indicate the presence of a hazard which could result in corruption of software or damage to equipment or property. The information icon alerts the reader of important facts and conditions. LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 13: Document Conventions

    • Dimensions are provided both in inches and millimeters. If it is not specifically mentioned then the dimension is in millimeters. LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 15: Lon Application

    Corporation. This protocol is designed for communication in control networks and is a peer- to-peer protocol where all the devices connected to the network can communicate with each LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 16: Hardware And Software Modules

    ServicePinMsg = Yes . The node address is sent to LNT via the LON bus, or LNT can scan the network for new nodes. The communication speed of the LON bus is set to the default of 1.25 Mbit/s. This can be changed by LNT. LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 17: Lon Operation Principle

    M15083-19 v3 A new device is added to LON Network Tool from the Device menu or by installing the device from the ABB LON Device Types package for LNT 505 using SLDT package version 1p2 r04. LON, 670 series Communication protocol manual...
  • Page 18: Lon Net Address

    Function block First LON address in function block EVENT:1 1024 EVENT:2 1040 EVENT:3 1056 EVENT:4 1072 EVENT:5 1088 EVENT:6 1104 EVENT:7 1120 Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 19: Command Handling

    Command handling M15083-80 v4 Commands are transferred using transparent SPA-bus messages. The transparent SPA-bus message is an explicit LON message which contains an ASCII character message following the LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 20 SPA parameters for block command BL_CMD SCSWI19 1 I 5545 SPA parameters for block command BL_CMD SCSWI20 1 I 5571 SPA parameters for block command Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 21 SPA parameters for cancel command CANCEL SCSWI13 1 I 5395 SPA parameters for cancel command CANCEL SCSWI14 1 I 5419 SPA parameters for cancel command Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 22 SPA parameters for select SELECTClose=01, so on. (Open/Close) command SELECTOpen=00, SCSWI05 1 I 5200 SPA parameters for select SELECTClose=01, so on. (Open/Close) command Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 23 SPA parameters for select SELECTClose=01, so on. (Open/Close) command SELECTOpen=00, SCSWI31 1 I 5825 SPA parameters for select SELECTClose=01, so on. (Open/Close) command Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 24 SPA parameters for operate ExcClose=01, so on. (Open/Close) command ExcOpen=00, SCSWI22 1 I 5610 SPA parameters for operate ExcClose=01, so on. (Open/Close) command Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 25 3 I 94 SPA parameter for position to be substituted Sub Value SXCBR15 3 I 120 SPA parameter for position to be substituted Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 26 3 I 587 SPA parameter for position to be substituted Sub Value SXSWI23 3 I 606 SPA parameter for position to be substituted Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 27 SXSWI01 3 I 197 SPA parameter for substitute enable command Sub Enable SXSWI02 3 I 215 SPA parameter for substitute enable command Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 28 SXSWI27 3 I 683 SPA parameter for substitute enable command Sub Enable SXSWI28 3 I 702 SPA parameter for substitute enable command Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 29 SXSWI07 3 I 311 SPA parameter for update block command Update Block SXSWI08 3 I 329 SPA parameter for update block command Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 30: Horizontal Communication

    This value is transmitted to the receiving node and presented for the application by a multiple command receive function block (MULTICMDRCV). With horizontal communication, the input BOUND on MULTICMDSND must be set to 1. There are 10 MULTICMDSND and 60 LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 31: Configuration Of Lon Network Variables

    The network variable connections are done from the NV Connection window. From LNT window select Connections/ NVConnections/ New. en05000719.vsd IEC05000719 V1 EN-US Figure 4: The network variables window in LNT LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 32: Communication Ports

    (ADM), and it is used for LON, SPA, IEC 60870-5-103 and DNP communication. In the following figure, X311 ports A/B are for SPA, IEC103 or DNP3 and X311 ports C/D are for LON protocol. LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 33 Connect the incoming optical fiber to the RX receiver input, and the outgoing optical fiber to the TX transmitter output. Pay special attention to the instructions concerning handling and connection of fiber cables. LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 35: Lon Settings

    Values (Range) Unit Step Default Description Operation Operation TimerClass Slow Slow Timer class Normal Fast TimeDomain Local without DST Local with DST Time domain Local with DST LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 37: Lon Technical Data

    Section 5 LON technical data Section 5 LON technical data Technical data IP14442-1 v1 M11927-1 v2 Table 6: LON communication protocol Function Value Protocol Communication speed 1.25 Mbit/s LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 39: Establishing Connection And Verifying The Lon Communication

    DomainID Domain identification number SubnNetAddr* 0 - 255 Subnet address Step: 1 NodeAddr* 0 - 127 Node address Step: 1 *Can be viewed on the local HMI LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 40: Optical Budget Calculation For Serial Communication With Lon

    Maximum total attenuation 11 dB 7 dB 6.1.2.2 Reference M11738-3 v2 We refer to document: LNT 505 Operator’s Manual 1MRS751706-MUM, Issued: 31.10.99, Program rev: 1.1.1 Doc. version: B. LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 41: Lon Functions

    EVENT Input signals Name Type Default Description BLOCK BOOLEAN Block of function INPUT1 GROUP Input 1 SIGNAL INPUT2 GROUP Input 2 SIGNAL Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 42: Settings

    AutoDetect Reporting criteria for input 1 OnSet OnReset OnChange AutoDetect EventMask2 NoEvents AutoDetect Reporting criteria for input 2 OnSet OnReset OnChange AutoDetect Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 43 AutoDetect Reporting criteria for input 13 OnSet OnReset OnChange AutoDetect EventMask14 NoEvents AutoDetect Reporting criteria for input 14 OnSet OnReset OnChange AutoDetect Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 44: Operation Principle

    The outputs from the EVENT function are formed by the reading of status, events and alarms by the station level on every single input. The user-defined name for each input is intended to be used by the station level. LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 45: Multicmdrcv And Multicmdsnd

    The sending function block, MULTICMDSND, takes 16 binary inputs. LON enables these to be transmitted to the equivalent receiving function block, MULTICMDRCV, which has 16 binary outputs. LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 46: Design

    Output 2 OUTPUT3 BOOLEAN Output 3 OUTPUT4 BOOLEAN Output 4 OUTPUT5 BOOLEAN Output 5 OUTPUT6 BOOLEAN Output 6 OUTPUT7 BOOLEAN Output 7 Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 47: Signals

    Input 6 INPUT7 BOOLEAN Input 7 INPUT8 BOOLEAN Input 8 INPUT9 BOOLEAN Input 9 INPUT10 BOOLEAN Input 10 INPUT11 BOOLEAN Input 11 Table continues on next page LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 48: Settings

    "VALID" to 0 (zero) if its block does not receive any data within the time defined by tMaxCycleTime. LON connections are established using LON network tool (LNT). LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 49: Synchronization Alternatives

    Hardware time synchronization source IRIG-B AppSynch NoSynch NoSynch Time synchronization mode for Synch application SyncAccLevel Class T5 (1us) Unspecified Wanted time synchronization accuracy Class T4 (4us) Unspecified LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 51: Glossary

    United Nations-sponsored standards body within the International Telecommunications Union. CAN carrier module CCVT Capacitive Coupled Voltage Transformer Class C Protection Current Transformer class as per IEEE/ ANSI CMPPS Combined megapulses per second LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 52 Dynamic random access memory Disturbance report handler Digital signal processor Direct transfer trip scheme Ethernet configuration tool EHV network Extra high voltage network Electronic Industries Association Electromagnetic compatibility LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 53 IEC 60870-5-103 Communication standard for protection equipment. A serial master/ slave protocol for point-to-point communication IEC 61850 Substation automation communication standard LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 54 Line data communication module Local detection device Light-emitting diode LON network tool Local operating network Miniature circuit breaker Mezzanine carrier module Milli-ampere module Main processing module MVAL Value of measurement LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 55 A balanced serial interface for the transmission of digital data in point- to-point connections RS485 Serial link according to EIA standard RS485 Real-time clock Remote terminal unit Substation Automation Select-before-operate LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 56 Transmit (disturbance data) TNC connector Threaded Neill-Concelman, a threaded constant impedance version of a BNC connector Trip (recorded fault) TPZ, TPY, TPX, TPS Current transformer class according to IEC LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 57 Three times zero-sequence current.Often referred to as the residual or the earth-fault current Three times the zero sequence voltage. Often referred to as the residual voltage or the neutral point voltage LON, 670 series Communication protocol manual © Copyright 2017 ABB. All rights reserved...
  • Page 60 ABB AB Grid Automation Products SE-721 59 Västerås, Sweden Phone +46 (0) 21 32 50 00 Scan this QR code to visit our website www.abb.com/protection-control © Copyright 2017 ABB. All rights reserved.