4.5.5 Input device on/off

Each input device can be switched on/off. However, when the device to be switched off is in the external
input signal, also switch off the input signal.
Transmit command [9] [2], data No. [6] [0], and data.
Bit
Symbol
0
SON
1
LSP
2
LSN
3
TL
4
TL1
5
PC
6
RES
7
CR
POINT
The on/off status of all devices in the servo amplifier are the status of the data
received at last. Therefore, when there is a device which must be kept on,
transmit data which turns the device on every time.
Command
Data No.
[9] [2]
[6] [0]
b31
Command of each bit is transmitted to the master station as hexadecimal data.
Bit
Symbol
8
SP1
9
SP2
10
SP3
11
ST1/RS2
12
ST2/RS1
13
CM1
14
CM2
15
LOP
Set data
See below.
Bit
Symbol
16
17
18
19
20
STAB2
21
22
23
6 - 100
b1b0
1: On
0: Off
Bit
Symbol
24
25
26
27
CDP
28
CLD
29
MECR
30
31